Agilent Technologies Cell Phone Accessories 8935 series e6380a User Manual

Page of 320
Connectors
Connectors
Chapter 9
286
DATA IN
This connector provides a data input to the CDMA generator. 
Operating Considerations
Input level = TTL
Input impedance = 50k 
Ω
Data Rate = 1.2288 Mcps
DUPLEX OUT
This connector is an output for the RF generator, CDMA generator and tracking 
generator. 
Operating Considerations
Output impedance = 50 
Ω
The RF generator’s output is selected in the 
Output Port
 field. This field is available on 
the RF GENERATOR, CDMA GENERATOR, and SPEC ANL screens. 
CAUTION
Connecting a signal of >60 mW (17.78 dBm) to the DUPLEX OUT port can cause 
instrument damage (although internal protection circuits can typically withstand a 
short-duration signal of several Watts). 
If the overpower circuit is triggered (signified by a warning message at the top of the 
screen), remove the signal from the DUPLEX OUT port, and reset using 
Meas Reset
 
(press and release the 
Shift
 key, then the 
Hold
 key) or turn the Test Set off and on to reset 
it.
EVEN SECOND SYNC IN 
This port is an input for the even second clock from the base station under test. A 
positive edge on this connector starts two timers. One timer, after reaching terminal 
counts, starts CDMA frame clocks. The other timer starts pilot PN sequence generation. 
The 
Even Sec In
 field on the CDMA GENERATOR screen controls this port. See 
.
Operating Considerations
Input impedance = 50 k
Ω
 
Input level range = TTL