Dakota Digital PAC-2700 User Manual

Page of 6
 
 
 
MAN# 650264:B
 
Operation 
The electric cooling fan controller provides a way to run up to two electric engine cooling fans or one two speed cooling 
fan. (A second relay, sold separately, is required for two speed or dual fan operation). The controller monitors the engine 
temperature using a dedicated sender, or a gauge and its sender. When the engine temperature goes above a user 
adjustable set point, the fan is turned on with a relay. When the engine has cooled below a user selectable off 
temperature, the fan is shut off. Separate on and off temperatures can be set for the high and low fan outputs. The 
controller will also run the fan when the air conditioner requires, by detecting when the air conditioning clutch is engaged. 
 
The unit can be set to keep the fan running (if the engine is hot enough) after the key is turned off. Several delay times are 
available from no delay to five minutes. The display will countdown the seconds left before the fan is turned off. If the 
battery voltage drops too low, the fan will be turned off and a “Lo bAt” message will display for the remainder of the time.  
 
Settings for several gauge systems are included to make installation with a gauge easier. The included gauges are 
Stewart Warner, Classic Instruments, VDO, and Autometer. If the gauge being used isn’t included, a custom calibration 
option allows the system to be calibrated to any gauge with clear numerical temp markings. This is accomplished by 
setting the controller to match the marks on the gauge with a few steps described in detail in the installation instructions.  
 
IMPORTANT NOTE!!!: If using a gauge with this unit, always ensure that your gauge is working properly. If the gauge is not reading 
correctly, the fan control unit will not have correct temperature information and cannot be guaranteed to properly control the fan, 
possibly leading to overheating and engine damage.   
If the gauge uses a two-wire temperature sender (such as Autometer full sweep) use of a dedicated Dakota Digital sender is 
required.   
 
If a gauge is not used, ONLY a Dakota Digital 300ºF sender should be used. Other senders may not give a correct reading to 
the control unit. 
 
Custom gauge calibration requires numerical marks, stock “C-NORMAL-H” type gauges cannot be accurately calibrated to. 
 
Required components for installation: 
The PAC-2700 is shipped with necessary components for use with a single fan on a gauged system. These parts include: 
 
PAC-2700 module 
 
RLY-3 relay with wiring harness 
 
Instruction manual 
For some options of the PAC-2700, additional components are required. These are listed below. 
- Second RLY-3 assembly (needed for dual fan or two speed fan operation) 
- 300ºF sender Dakota Digital temp sender (for operation without a gauge) 
 
Installation 
Note: Mount ONLY in vehicle cabin. Controller is not designed for engine compartment mounting. 
The terminal strip on this unit has 6 connections: 
1. Fan high relay  
Connect to the white wire on the high fan relay assembly 
 
 
 
 
(for single fan applications leave unconnected) 
2. Fan low relay  
Connect to the white wire on the low fan relay assembly 
3. Ground 
 
Connect to a good chassis ground 
4. Power 
 
Connect to a fused 12V battery  
5. Sender 
 
Connect to the engine temperature sender wire. 
6. A/C clutch 
 
Connect to the cycle switch on systems with air conditioning 
 
 
 
 
(on systems without air conditioning leave unconnected) 
7. Ignition 
 
Connect to a circuit which has +12V only with the ignition key ON. (switched power) 
 
Relay wiring: 
White   
 
Connect to control unit 
Green   
 
Connect to fused 12V battery circuit that can run cooling fan 
Red 
 
 
Connect to fused 12V battery 
Black   
 
Connect to cooling fan 
 
Factory Presets 
This controller comes preset to use a dedicated sender as follows: 
  
Dakota Digital Sender only (no gauge, see above for 300ºF sender options) 
 
One single speed fan 
 
205ºF on temperature 
 
200ºF off temperature  
 
30 sec Fan off delay 
 
If the factory settings don’t fit your application, you will need to go through the setup procedure on the following page. At 
anytime during the setup procedure, the key may be turned off and the settings up to that point will be saved.