TROUBLESHOOTING 
PROBLEM 
CAUSE 
SOLUTION 
Display reads “Er0” 
(lost memory) 
Setup memory lost, unit needs to be 
recalibrated 
Go through setup procedure, (see setup in this manual) 
Display reads “Er1” 
(shorted sender) 
Wrong gauge selected 
 
 
Gauge disconnected from sender 
(gauge option only) 
 
Sender is shorted 
 
Unit not connected to sender 
Select proper gauge in setup or use custom cal if 
needed 
 
Reconnect gauge to sender 
 
Check sender wire for short to ground, look for pinched 
sender wire or bare connection touching ground 
 
Connect SENDER terminal on unit to sender circuit 
Display reads “Er2” 
(open sender) 
Wrong gauge selected 
 
 
Sender not connected 
 
Unit not connected to sender 
Use setup to select proper gauge, or use custom cal if 
needed 
 
Reconnect wire to sender 
 
Connect SENDER terminal on unit to sender circuit  
Display reads “Er3” 
Setup data is out of valid range 
Go through setup again, custom cal may be incorrect  
Display reads “bAt” 
when attempting to go 
into setup 
+12v terminal does not have 
constant power 
Connect +12v terminal to fused battery connection. This 
terminal should have constant power at all times. 
Display alternates 
between “Lo” and “bAt” 
Battery voltage dropped too low 
during key off extended fan on time 
Ensure battery is fully charged. Check and replace weak 
battery. Shorten fan delay time to prevent excessive 
battery drain. 
Fan turns on late, or 
not at all  
Unit has no power 
 
 
 
Broken/shorted wire to sender 
 
Wrong gauge is selected 
(gauge setup) 
 
Wrong sender used  
(for no gauge setup) 
 
 
On temperature in setup is too high 
 
 
Fan not connected properly 
 
 
Alternator overcharging 
(Analog gauge applications only) 
 
With key on, hold SW1, if the display doesn’t show a 
temperature after a few seconds, check battery and 
ground connections. 
 
Check wire to sender for breaks or shorts and repair. 
 
Hold SW1, if temperature read is lower than expected or 
doesn’t match gauge, redo setup. 
 
For sender only applications ONLY a Dakota Digital 
300ºF sender can be used. Other senders may not give 
a correct temperature reading. 
 
Hold SW1, if temperature read is above the desired on 
temperature, and fan is not running, redo setup. 
 
Remove fan output from unit and short wire to ground. If 
fan does not run, check relay and fan connections. 
 
Use a voltmeter to measure the voltage at the battery 
while the engine is running. If this voltage is above 15v 
the unit may turn the fan on later than expected. Either 
correct overcharging problem or set on temp lower to 
compensate. 
Fan runs constantly 
Controller has an error 
 
Fan off temp too low 
 
Broken/shorted wire to sender 
 
Wrong gauge is selected 
Check display for error message 
 
Increase off temp in setup 
 
Check wire to sender for breaks or shorts and repair. 
 
Select appropriate gauge in setup, or custom calibrate if 
your gauge is not supported.