Dell PowerVault MD32xxi Configuration Guide for VMware ESX4.1 Server Software 
 
 
Page 16 
 
 
esxcfg-nics –l 
 
The output will look similar to this: 
 
Name    PCI          Driver     Link Speed Duplex MAC Address          MTU 
vmnic0 03:00.00 bnx2 Up 1000Mbps Full       00:21:9b:8b:4b:b0 1500 
This will list all of the adapters in the system. Assign the NICs that are physically connected to the SAN 
infrastructure and to the vSwitch. The following command assumes that we are assigning vmnic1, vmnic2, 
and vmnic3 to the vSwitch. 
 
esxcfg-vswitch –L vmnic1 vSwitch2 
 
esxcfg-vswitch –L vmnic2 vSwitch2 
 
esxcfg-vswitch –L vmnic3 vSwitch2 
 
Once again, to verify the configuration type the following command to list the vSwitch information: 
 
esxcfg-vswitch –l 
 
Your output will look similar to the following. Note the new vmnics that were assigned to the vSwitch 
under uplinks. 
 
Switch Name    Num Ports    Used Ports    Configured Ports MTU Uplinks 
vSwitch2  
64  
       9  
 
   64  
 
    9000 
 
 
PortGroup Name  VLAN ID  Used Ports  
Uplinks 
iSCSI3    
 
0  
 
1  
 
vmnic1,vmnic2,vmnic3 
iSCSI2    
 
0  
 
1  
 
vmnic1,vmnic2,vmnic3 
iSCSI1    
 
0  
 
1  
 
vmnic1,vmnic2,vmnic3  
 
Adding a NIC can also be configured and verified in the vCenter GUI. Remember that the polling of 
vCenter is not instant so a refresh might need to occur to see the latest changes. To configure this same 
process from the GUI, first navigate to the Networking section on the ESX host you are configuring. 
Configuration -> Networking
 
From here, click Properties on the vSwitch2.