DeWALT MD3220I User Manual

Page of 41
Dell PowerVault MD32xxi Configuration Guide for VMware ESX4.1 Server Software 
 
 
Page 31 
 
 
Dell/VMware alliance home page:  
  
 
 
Appendix A  
This appendix details an example of how to over commit the number of VMkernel ports to the physical NICs. This is 
usually done in environments in which the NIC is capable of handling multiple sessions such as 10GbE. This can also 
be done in larger environments combined with a PowerVault SAN to help achieve maximum bandwidth to the 
SAN. 
 
In this appendix example we are using 2 physical NICs and assigning 3 VMkernel ports to each one for a total of 6 
sessions to the SAN. 
 
Step A1: Configure vSwitch and Enable Jumbo Frames 
Follow the Step 1 configuration steps in the main document as there are no changes for adding multiple 
VMkernel ports. 
 
Step A2: Add iSCSI VMkernel Ports 
The following command will add a new iSCSI VMkernel Port named iSCSI1 on the vSwitch created in the 
previous step. 
 
esxcfg-vswitch –A iSCSI1 vSwitch2 
 
This next command will configure the IP Address, Subnet Mask and enable Jumbo Frame support for the 
new VMkernel Port iSCSI1 
 
esxcfg-vmknic –a –i 10.10.5.173 –n 255.255.255.0 –m 9000 iSCSI1 
 
Following the example from before we are just adding more VMkernel ports. We need to create 5 more 
VMkernel Ports named iSCSI2, iSCSI3, iSCSI4, iSCSI5 and iSCSI6. Then configure the IP addresses, subnet 
masks and enable Jumbo Frames. 
 
esxcfg-vswitch –A iSCSI2 vSwitch2 
esxcfg-vmknic –a –i 10.10.5.174 –n 255.255.255.0 –m 9000 iSCSI2 
 
esxcfg-vswitch –A iSCSI3 vSwitch2