Mitsubishi Motors Oven FR-A5AP User Manual

Page of 58
14
3.3. Terminals
Symbo
l
Terminal
Remarks
Description
PA1
PLG A-phase signal input terminal
PA2
PLG A-phase inverse signal input
terminal
PB1
PLG B-phase signal input terminal
PB2
PLG B-phase inverse signal input
terminal
For information on the
pulse signals, refer to
page 11.
A-, B- and C(Z)-phase signals are input
from the PLG
PC1
PLG C(Z)-phase signal input terminal
PC2
PLG C(Z)-phase inverse signal input
terminal
PAR
A-phase terminal resistor terminal
Factory-connected with "PA2" by the
jumper. Remove the jumper when the
terminal resistor is not needed
PBR
B-phase terminal resistor terminal
Factory-connected with "PB2" by the
jumper. Remove the jumper when the
terminal resistor is not needed
PCR
C(Z)-phase terminal resistor terminal
Factory-connected with "PC2" by the
jumper. Remove the jumper when the
terminal resistor is not needed
5V
DC power (positive) input terminal
SG
DC power ground terminal
4.75 to 6VDC (Current
consumption 50mA)
PLG power supply common terminals.
Input PLG power. Connect the positive
side to 5V and the ground side to SG.
Also, connect the shield of the shield wire
to SG.