Symptom: 
What it may indicate: 
What you should do: 
10.0  Air charging 
system doesn’t 
build air. 
(a) Governor malfunction*. 
(b) Restricted discharge line.
(c) Air  dryer  heater  malfunction: 
exhaust port frozen open.
(d) Compressor malfunction.
 
Go to Test 4 on page 25.
 
See 9.0(f).
 
Replace air dryer heater.
 
Replace the compressor only after making 
certain  the  preceding  conditions  do  not 
exist.
11.0 Compressor 
safety valve 
releases air 
(Compressor 
builds too much 
air).
(a) Restricted discharge line. 
  
If discharge line is restricted:
    By more than 1/16" carbon build up, 
replace  the  discharge  line  (see  Table  A, 
column  2,  on  page  13  for  recommended 
size) and go to Test 3 on page 24.   
    By  other  restrictions  (e.g.  kinks). 
Replace the discharge line. See Table A, 
column  2,  on  page  13  for  recommended 
size.  
 
The  discharge  line  must  maintain  a 
constant slope down from the compressor 
to the air dryer inlet fitting to avoid low points 
where  ice  may  form  and  block  the  flow.  
If, instead, ice blockages occur at the air 
dryer inlet, insulation may be added here, 
or if the inlet fitting is a typical 90 degree 
fitting, it may be changed to a straight or 
45  degree  fitting.    For  more  information 
on  how  to  help  prevent  discharge  line 
freeze-ups, see Bendix Bulletins TCH-08-
21 and TCH-08-22 (Appendix B).  Shorter 
discharge line lengths or insulation may be 
required in cold climates. 
 
Inspect air lines and verify check valves are 
operating properly.  
 
Ensure discharge line is installed into the 
inlet of the air dryer and delivery is routed 
to the service reservoir.
 
Verify relief pressure is 250 psi. Replace if 
defective. 
 
Go to Test 6 on page 25.
 
Go to Test 4 on page 25.
Damaged 
discharge 
line shown.
* Note: For the Bendix
®
 DuraFlo
 596
 
air compressor, not only 
the governor, but also the SV-1
 synchro valve used would 
need to be tested.  See Bulletin TCH-001-048.
(b) Downstream air brake system check 
valves or lines may be blocked or 
damaged.  
(c) Air dryer lines incorrectly installed. 
(d) Compressor safety valve 
malfunction. 
(e) Compressor unloader mechanism 
malfunction. 
(f) Governor malfunction.