BENDIX BW2398 User Manual

Page of 32
25
1.  Ensure that the governor control line from the 
reservoir is located at or near the top of the 
reservoir. (This line, if located near the bottom of 
the reservoir, can become blocked or restricted 
by the reservoir contents e.g. water or ice.)   
Bendix
®
  Compressors:  Park  vehicle,  chock 
wheels, and follow all standard safety procedures.  
Remove the governor and install a fitting to the 
unloader  port.   Add  a  section  of  air  hose  (min 
1  ft  long  for  a  1/2"  diameter  line)  and  a  gauge 
to the fitting followed by a shut-off valve and an 
air source (shop air or small air tank).  Open the 
Test 5:  Governor Control Line
Test 6:  Compressor Unloader Leakage 
1.  Inspect control lines to and from the governor 
for  restrictions  (e.g.  collapsed  or  kinked). 
Repair as necessary.
2.  Using  a  calibrated  external  gauge  in  the 
supply reservoir, service reservoir, or reservoir 
port of the D-2
 governor, verify cut-in and 
cut-out  pressures  are  within  vehicle  OEM 
specification.
3.  If the governor is malfunctioning, replace it.
Tests (continued)
Test 4:  Governor Malfunction 
2.  Perform proper reservoir drain intervals and air 
dryer cartridge maintenance per Maintenance 
Schedule and Usage Guidelines (Table A on 
page 13).  
3.  Return the vehicle to service.
shut off and charge the unloader port by allowing 
air  pressure  to  enter  the  hose  and  unload  the 
compressor.  Shut off the air supply and observe 
the gauge.  A steady reading indicates no leakage 
at the unloader port, but a falling reading shows 
that the unloader mechanism is leaking and needs 
to be serviced.