B&B Electronics 232XS5 User Manual

Page of 15
 
232XS5-1005 Manual 
 
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 
B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445  
 
Table 4.  DTE MASTER PORT CHART 
 
 
 
The 232XS5 supports the following RS-232 signals: TD, RD, 
SG, RTS, CTS, DCD, DSR and DTR. 
 
 
NOTE:  All other lines are not connected. 
 
The Smart Switch selects port A as the default port at power up. 
Table 3.  DCE MASTER PORT CHART 
Master Port 
(DCE)    
 
Signal 
A,B,C,D & E Ports
(DTE) 
Pin# Direction 
Description 
Pin# Direction 
3 Input 
Transmit 
Data 
(TD)  3 Output 
2 Output 
Receive 
Data 
(RD) 
2  Input 
Input 
Request to Send (RTS) 
Output 
Output 
Clear to Send (CTS) 
Input 
Input 
Data Terminal Ready (DTR)
Output 
Output 
Data Set Ready (DSR) 
Input 
Output 
Data Carrier Detect (DCD) 
Input 
5 <-------> 
Signal 
Ground 
(SG) 
5  <-----> 
Master Port 
(DTE)    
 
Signal 
A,B,C,D & E Ports
(DCE) 
Pin# Direction 
Description 
Pin# Direction 
3 Output 
Transmit 
Data 
(TD) 
3  Input 
2 Input 
Receive 
Data 
(RD)  2 Output 
Output 
Request to Send (RTS) 
Input 
Input 
Clear to Send (CTS) 
Output 
Output 
Data Terminal Ready (DTR)
Input 
Input 
Data Set Ready (DSR) 
Output 
Input 
Data Carrier Detect (DCD) 
Output 
<-------> 
Signal Ground (SG) 
<-----> 
 
  
232XS5-1005 
Manual 
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 
B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445  
6
 
 Serial Data Configuration 
 
In order for the host device that is connected to the master port 
to select any of the five ports, the Smart Switch must be set to 
match the host's communication format.  Dipswitch “SW1” is used to 
select the communication format of the Smart Switch.  Switch 
positions 1 through 3 select the baud rate.  Switch position 4 selects 
7 or 8 data bits.  Switch position 5 determines if parity is enabled or 
disabled. 
 
NOTE:  A data format of 7 data bits, no parity and one stop is 
 not 
allowed. 
 
Switch position 8 selects the port configuration, see section 
titled "Port Configuration".  Refer to Table 1.  Always power down 
the smart switch when changing switch settings. 
 
 RS-485 Support 
 
RS-485 support may be 
provided by adding a Model 
485SD9TB RS-232 to RS-485 
converter or other recommended 
device to the slave ports of the 
232XS5. 
Port power of about 30 mA may be applied through the DTR line 
(Pin 4) of the slave ports with jumper JP1-JP5.  Normally, the 
jumpers are set to allow DTR to pass from the master port.  To 
enable port power on a slave port, move the jumper from the“OFF” 
to “ON” position on the corresponding JP jumper.  To allow DTR to 
pass from the master port to the slave port, move jumper from “ON” 
to “OFF” on the corresponding JP jumper.  DTR can only pass 
through when the port is selected and the jumper is set to the “OFF” 
position on the corresponding slave port JP jumper. 
 
Table 5.  Port Power Jumpers 
* = FACTORY DEFAULT 
Jumper 
JP1-5 
 
Setting 
“OFF” DTR 
passed 
“ON” Port 
Power