Brother PR650C Owner's Manual

Page of 18
14
4.  Programming
4-1 Selecting hardware on output side
  Output is NPN open collector output.
          PCB internal circuit
    On the assumption that output activates the air valve (option part).
  Use a 24 VDC relay if not using a 24 V air valve.
          PCB internal circuit          External 24V relay
    No fuses are built in the output circuit. To prevent circuit damage when forming short output, it is
recommendable to install an external fuse on each output.
4-2 Selecting hardware on input side
    Input is non-insulating IC input.
         PCB internal circuit                  Example of connection with proximity sensor
  Insulate input using a relay if not using a contact switch or a 24 V sensor.
        PCB internal circuit                       External relay
    Use a relay for electronic circuit whose maximum applicable load is 5 V and 1m A or less.
+24V
Load
I = 70mA
COM terminal
Output
terminal
+24V
Load
  L
COM terminal
Output
terminal
Power
+24V
0V
+5
4.7K
Ω
Vcc
0V
Input terminal
Sensor output
Sensor output
NPN open collector
+24V
0
+5
4.7K
Ω
  L
Input terminal
External
apparatu