Bosch Appliances Security Camera EX27 User Manual

Page of 48
 
 
 
42
Poor 
Picture 
Quality 
 
 
Snowy 
Image 
(cont’d.) 
 
 
Horizontal 
Scan Lines, 
Rolling Up 
or Down 
 
 
 
 
 
 
 
 
 
 
Negative, 
scrambled, 
or faded 
image 
 
 
 
 
 
 
Noisy Power 
Supply 
 
 
 
Ground Looping on 
video cable 
 
 
 
 
 
 
 
 
24V ac operation 
 
 
 
Low voltage
 
 
 
 
 
 
Check connections. 
Relocate or replace 
power supply. 
 
 
Check the coax cable 
shield is not touching 
ground, e.g. at 
couplings. 
An electrically 
isolated circuit board 
or isolation 
transformer may be 
required. 
 
Line Lock adjustment 
required. 
 
 
Check voltage at 
input power cable. 
Must be >10.5V dc or 
>12V ac.