CC408 | Operators Guide | 12.   Fault Analysis Mode 
EN | 12 
 
Bosch Security Systems | 5/04 | 920050O.OG.112 
12.   Fault Analysis Mode 
If a fault occurs, the FAULT or MAINS indicators 
flash and the codepad beeps once every minute. 
12.1 AC 
Fail 
If the AC mains supply fails, the MAINS indicator 
flashes until the AC mains supply is restored. 
Pressing the [#] key once acknowledges the fault and 
stops the codepad from beeping once every minute. 
12.2 System 
Faults 
How to Determine the Type of System Fault 
To determine all system faults other than the AC 
mains supply, enter Fault Analysis Mode: 
1.  Hold down the [5] key until two beeps sound. 
The FAULT indicator lights steadily and the 
STAY and AWAY indicators flash in unison. 
Any zone indicators displayed indicate the type 
of fault that occurred. See Table 10 for the list of 
system faults that can occur. 
2.  To further determine the type of fault condition, 
hold down the key that corresponds to the zone 
indicator displayed. 
3.  To exit Fault Analysis Mode and return to the 
disarmed state, press the [#] key. The FAULT 
indicator remains displayed and the codepad 
stops beeping once per minute. 
12.3 Fault 
Descriptions 
Table 10:  Fault Condition Indicators 
 
Zone LED 
FAULT Condition 
Battery Fail 
Date/Time 
Sensor Watch 
Horn Speaker Fail 
Telephone Line Fail 
E2 Fault 
Fuse Fail 
Communication Fail 
Battery Fail 
A battery fail fault registers when the system detects 
a low capacity back-up battery. The system 
automatically performs a Battery Test every 4 hours 
and every time the system is armed. 
Date and Time 
The date and time fault registers every time the 
system powers down. This type of fault does not 
cause the FAULT indicator to display on the 
codepad unless your installer has programmed the 
automatic arming time. See Section 11. Setting the Date 
and Time to program the date and time. 
Sensor Watch Fail 
A sensor watch fault registers because one or more 
detection devices failed to notice any movement 
during the disarmed state for the time period 
programmed by your installer. The fault clears when 
the zone in question detects movement and resets. 
While in Fault Analysis Mode, hold down the [5] key 
until two beeps sound. The indicator lights that 
corresponds to the faulted zone. 
Horn Speaker Fail 
A horn speaker failure fault registers when the 
system detects the horn speaker is disconnected. This 
fault clears once the horn speaker is reconnected. 
Your installer needs to program the system for this 
feature to operate. 
Telephone Line Fail 
A telephone line failure fault registers when the 
system detects the telephone line is disconnected 
from the control panel. Your installer needs to 
program the system for this feature to operate. 
E2 Fault 
An E2 failure fault registers when the system detects 
an internal checksum error. Contact your installer as 
soon as this fault displays. 
Fuse Fail 
A fuse failure fault occurs when either of the two 1 A 
fuses are blown. Contact your installer as soon as this 
fault displays. 
Communication Fail 
A communication fail fault registers when the control 
panel fails to communicate with the receiving party 
(for example, a monitoring company, mobile phone, 
pocket pager, and so on). The communication fault 
clears once the control panel successfully reports to 
the receiving party.