After installing the appliance, ensure 
that the plug is easily accessible.
(see Electrical connection)
Some  models:
The plastic housing on the water 
connection contains an electric valve, 
the connecting cables are in the supply 
hose. Do not cut through this hose, 
do not immerse the plastic 
housing in water.
ã=
Warning
If the appliance is not in a cavity and a 
side panel is accessible, the door hinge 
area must be covered at the side 
for reasons of safety (risk of injury). 
The covers are available as optional 
accessories from customer 
service or specialist outlets.
Delivery
Your dishwasher has been checked 
thoroughly in the factory to ensure that it is 
in working order. This may cause small 
water stains. These will disappear after the 
first wash cycle.
Technical specifications
Weight:
max. 60 kg
Voltage:
220–240 V, 50 Hz or 60 Hz
Connected load:
2.0–2.4 kW
Fuse:
10/16 A (UK 13A)
Water pressure:
at least 0.05 MPa (0.5 bar), maximum 
1 MPa  (10 bar).  At  a  higher  water 
pressure: connect pressure-reducing valve 
ahead.
Inlet rate:
minimum 10 litres/minute
Water temperature:
cold water; hot water max. temperature 
60 °C.
Installation
The required installation dimensions can 
be found in the installation instructions. 
Level the appliance with the aid of the 
height-adjustable feet. Ensure that the 
appliance is situated securely on the floor.
A built-under or integrated appliance 
which is installed subsequently as a 
free-standing appliance must be 
secured to prevent it from overturning, 
e.g. by screwing it to the wall or by 
installing it under a continuous worktop 
which is screwed to adjacent 
cupboards.
The appliance can easily be 
installed in a fitted kitchen between 
wooden and plastic walls. 
Waste-water connection
The required work sequence can be 
found in the installation instructions. If 
required, fit a siphon with an drainage 
connection. 
Connect the waste-water hose to the 
drainage connection of the siphon with 
the enclosed parts.
Ensure that the drainage hose is not 
kinked, crushed or twisted and that 
there is no cover plate in the drainage 
to prevent the waste water from flowing 
out!
Fresh water connection
Connect the fresh-water connection to 
the tap according to the installation 
instructions with the enclosed parts.
Ensure that the fresh-water connection 
is not kinked, crushed or twisted.
When replacing the appliance, always 
use a new water supply hose.
Water pressure:
at least 0.05 MPa (0.5 bar), maximum 
1 MPa  (10 bar).  At  a  higher  water 
pressure: connect pressure-reducing valve 
ahead.
Inlet rate:
minimum 10 litres/minute
Water temperature:
cold water preferred; hot water max. 
temperature 60 °C.