Woodstock SHOP FOX W1736 User Manual

Page of 28
-14-
SET 
UP
W1736 Overarm Router
Depending on the type of air fitting you have on the end 
of your air hose, you may need to replace the included 
male 1/4 NPT fitting with the style of 1/4 NPT fitting suit-
able for the female quick connect in your shop.
To connect your overarm router to the air compressor, 
do these steps:
1.  Regulate the pressure of your air compressor to 60 
PSI. NEVER exceed 115 PSI when your overarm rout-
er is connected to the air compressor or damage 
may occur! 
2.  Connect your air hose to the small hose attached to 
the foot switch.
 
Note: If you hear any air leaks, locate the leaky fit-
tings quickly and immediately disconnect the over-
arm router from the air system. Tighten the fittings 
and reconnect them to the air system. If the compo-
nents are still leaking, reinstall them with a liquid 
thread sealer to ensure a sealed fit.
Connecting to Air
The purpose of a test run is to ensure that the router 
motor drops while the foot switch is pressed and raises 
when the foot switch is released. 
Note: Before performing the test run, make sure that the 
router is adjusted high enough so that it will not hit the 
table pin when the foot pedal is pressed.
Perform a test run now by pushing and releasing the foot 
switch.
•  If the router does not perform correctly, then the 
valves will likely need to be adjusted. See 
Adjusting 
Valves on Page 15.
Test Run
DISCONNECT  air  line  before  you 
attempt  to  remove  any  air  fittings. 
Otherwise,  serious  personal  injury  to 
you or others may occur!
If the router is plunged into the pin or 
table,  the  router  bit  may  break  apart 
sending metal fragments flying toward 
the operator. Always adjust the plunge 
depth  correctly  before  operating  the 