Lynx L-LS User Manual

Page of 3
                                                                                                                                                                                                    
eDART System User Guide
                                                                                                                                                                                        
Appendix
34
Step 4.
Hold the limit switch in place and use a ty-wrap to tighten 
it down to the tie-bar. See figure 29.
More than one ty-wrap can be tied together if the tie-bar is 
large.
              Figure 29:  Lynx™ Mold-Closed Limit Switch L-LS side view
Table 26: Figure Labels
Step 5.
Plug a Lynx™ cable between the limit switch and the 
eDART System™.
Step 6.
Run the machine to ensure proper use, while monitoring 
the eDART™ software.
C
A
L-LS
B
D
A
Moving Half
B
Ejector Plate
C
Tie Bar
D
Tighten Ty-Wrap
U

Always power down before working on 
any equipment.