LSI SAS2 User Manual

Page of 42
SAS2 Integrated RAID Solution User Guide
Appendix A: 
 | 
Commands
LSI Corporation Confidential 
August 2010
Page 39
Sample Output
Following is an example of the information that the STATUS command returns when a 
volume resynchronization is in progress:
Background command progress status for controller 0...
IR Volume 1
Volume ID                               : 6
  Current operation                       : Synchronize
  Volume status                           : Enabled
  Volume state                            : Degraded
  Physical disk I/Os                      : Not quiesced
  Volume size (in sectors)                : 70311936
  Number of remaining sectors             : 68250624
  Percentage complete                     : 2.93%
Following is an example of the status information that the STATUS command returns if 
a background volume operation is not in progress:
Background command progress status for controller 0...
IR Volume 1
  Current operation                       : None
  Volume ID                               : 6
  Volume status                           : Enabled
  Volume state                            : Optimal
  Physical disk I/Os                      : Not quiesced
The possible values for the fields in the status data are as follows:
Current operation: Synchronize, Consistency Check, OCE, Background Init, or None
Volume status: Enabled or Disabled
Volume state: [Inactive] OptimalDegraded, Missing, or Failed
Physical disk I/Os: Quiesced or Not quiesced
A.3.7  LIST Command
The LIST command displays a listing of all controllers present in system, along with 
each corresponding controller index. You use the controller index as an input 
parameter for other SAS2IRCU commands.
Command Line
sas2ircu list
Parameters
None
Program Return Value
0x00
SUCCESS: Command completed successfully.
0x01
FAILURE: Command failed.
0x02
ADAPTER_NOT_FOUND: Cannot find specified adapter.
Sample Output
Following is an example of the output of the LIST command. The format and fields in 
the output may vary depending on the types of installed controllers.
Adapter
Vendor Device
SubSys
SubSys
 Index   Type      ID     ID     Pci Address      Ven ID  Dev ID
 ----- --------- ------ ------ ----------------  -------  ------
   0    SAS2008   1000h   72h    00h:01h:00h:00h  1000h    00dah
   1    SAS2008   1000h   72h    00h:05h:00h:00h  1000h    00dah