55
FORWARD 
FORWARD N LINES 
skip forward N lines in 
buffer 
REVERSE 
REVERSE N LINES 
skip back N lines in 
buffer 
 
The commands FORWARD and REVERSE must be followed by the number of lines the 
user wants to move in the buffer.  The command will not execute if the number of lines 
is omitted. 
 
The user may also clear the buffer by using the command CLEAR or by selecting CLEAR 
BUFFER
 from the pull-down menu.  All data stored in the device buffer will be erased 
and is not recoverable.  The sys admin may inhibit this ability on a per-user basis by 
either creating the user ID without this ability or editing the user parameters after the 
user is created. 
 
The CAT and CAT WITH FILTER commands allow a user to output the content of the 
device buffer to the screen. This allows a user to capture the contents of a device buffer 
by using the telnet client/terminal emulation software’s texr capture capabilities. 
 
CAT outputs the data in the buffer exactly as it was received without any additional 
formatting. 
 
CAF outputs the data in the buffer by applying the same formatting that is used by the 
TOP, BOTTOM, NEXT
, and PREVIOUS type commands. Characters are counted and a 
<CR><LF>
 is added after 80 characters if one is not found in the data. Due to the 
counting, escape sequences may not be preserved. Tabs are considered one character.