34
 
Detect Double Feed (1400u Only) 
This function detects the feeding of more than one sheet at a time. If a double feed is detected, you can opt 
to be notified. The default setting for this function is stop. 
 
 
    
ΠNOTE:
 
 
With this function, ultrasonic waves are aimed at the document to detect double feed by the level at 
which the waves pass through the sheets. The function can detect double feed even when sheets 
are superimposed exactly on top of each other, but it may not be detected properly with some paper 
thicknesses and when creasing and other factors are present. 
 
When important documents are to be scanned, check the number of document sheets and the 
number of scanned image sheets. 
 
When scanning a document containing paper in different sizes, double feed can be detected when 
this function is selected. 
 
The default for Detect Double Feed is ON. 
 
1. Navigate to your scanning application and select Settings
2. Click the More button in the Settings dialog box. 
3. Select the Detect Double Feed button in the Feeding Features section of the Advanced 
Settings dialog box.  
4. If the Detect Double Feed function operates incorrectly, adjust the sensitivity level by selecting one 
of the levels in the Sensitivity drop-down list. 
 
 
 
 
 
 
 
 
 
 
 
5. Select one of the following from the Action drop-down list: 
 
 
 
 
If a Multifeed occurs, remove the document from the ADF (Automatic Document Feeder). For instructions 
on removing papers jams, refer to 
Clearing Paper Jams
 Either separate the multifed pages and/or reinsert the 
document(s) into the ADF and press the STOP/START button to resume scanning. 
 
 
 
 
 
High 
Select this when feeding thin documents.
 
Normal 
This is the standard sensitivity.
 
Low   
Select this when feeding thick documents.
 
Beep                 Signal alert 
Stop Scanning   Stops the scanning process for operator attention. This is the default setting.