Filter Element Servicing (cont.) 
 
4.3.2  Inspection – Normal conditions. 
 
At each 150 hours of operation or upon activation of the low inlet pressure warning light, 
Remove the elements and inspect in accordance with paragraphs 4.3.1a, b, c and d. 
Elements should be replaced after 1500 hours in service. 
 
 
4.4 
Oiling The Filter Element 
 
 
CAUTION: Use only Oil, PN 40 – 10 or PN 40-10CW 
 
AeroFilter oil is a compounded mineral based blend, formulated with special polymers to form 
the tack barrier.  A dye has been added to show where the oil has been applied. Eventually 
the red color will fade but the oil will remain. 
 
CAUTION: Never use the filter element without AeroFilter oil. 
 
 
 
DO NOT use Engine Oil 
 
 
DO NOT use Transmission Oil 
 
 
DO NOT use Hydraulic Fluid 
 
 
DO NOT use Lightweight Oils (WD 40, LPS, etc) 
 
 
a)  Fill sprayer with recommended quantity of Aerofilter oil (8 Fluid Ounces). 
b)  Charge sprayer with compressed air.  
c)  Apply oil to the filter element with smooth, complete passes parallel to pleats.  
d)  Repeat 90 degrees to pleats.  
e)  Use all of the measured quantity of oil.  
f)  Wait 30 minutes for proper wicking and lightly re-oil any light areas. 
 
 NOTE 
Do not over-oil the element. Proper absorption is achieved when the filter media is 
completely wicked and any surplus oil has been allowed to drip from the element. 
 
 
The filter element is now ready for installation. Ref. Par. 4.2.