Thermador PR305PH Specification Guide

Page of 5
Page 3 of 5
PRG305PH  
 
30-INCH GAS PRO HARMONY
®
 RANGE
 
PROFESSIONAL SERIES, STANDARD-DEPTH, PORCELAIN COOKTOP SURFACE
FIGURE 4
5
" (127 mm) min.
to combustible
sidewalls
5" (127 mm) min.
to combustible
sidewalls
0" Clearance
to back wall
0" Clearance
to back wall
18
" (457 mm)
minimum
18" (457 mm)
minimum
30"
 (762 mm) min.
from bottom of overhead
hood to cooking surface.
36"
 (914 mm) min. if
hood contains 
combustible material 
30"
 (762 mm) min.
from bottom of overhead
hood to cooking surface.
36"
 (914 mm) min. if
hood contains 
combustible material 
30" (762 mm)
30" (762 mm)
13"
 
(330 mm) 
max.
cabinet 
depth
13"
 
(330 mm) 
max.
cabinet 
depth
CAUTION!
36" (914 mm) min.
to combustible
material 
from Cooking
Surface
CAUTION!
36" (914 mm) min.
to combustible
material 
from Cooking
Surface
30" – 36
" (762 – 914 mm)
wide hood
30" – 36
" (762 – 914 mm)
wide hood
Cabinet Clearances with Hood
       as defined in the “National Fuel Gas Code” (ANSI Z223.1, Current Edition). 
Clearances from non-combustible materials are not part of the ANSI Z21.1 
scope and are not certified by CSA. 
For Gas Supply & 
Electrical Zones
see Figure 4.
For Gas Supply & 
Electrical Zones
see Figure 4.
The range height is adjustable. 
The level of the range top must 
be at the same level or above 
the counter top level.
*35 ¾" (908 mm)  Min. range 
height with leveling legs fully 
retracted.
*37 ¼"  (946 mm) Max. range 
height with leveling legs fully 
extended.
The range height is adjustable. 
The level of the range top must 
be at the same level or above 
the counter top level.
*35 ¾" (908 mm)  Min. range 
height with leveling legs fully 
retracted.
*37 ¼"  (946 mm) Max. range 
height with leveling legs fully 
extended.
5
" (127 mm) min.
to combustible
sidewalls
5" (127 mm) min.
to combustible
sidewalls
0" Clearance
to back wall
0" Clearance
to back wall
18
" (457 mm)
minimum
18" (457 mm)
minimum
30"
 (762 mm) min.
from bottom of overhead
hood to cooking surface.
36"
 (914 mm) min. if
hood contains 
combustible material 
30"
 (762 mm) min.
from bottom of overhead
hood to cooking surface.
36"
 (914 mm) min. if
hood contains 
combustible material 
30" (762 mm)
30" (762 mm)
13"
 
(330 mm) 
max.
cabinet 
depth
13"
 
(330 mm) 
max.
cabinet 
depth
CAUTION!
36" (914 mm) min.
to combustible
material 
from Cooking
Surface
CAUTION!
36" (914 mm) min.
to combustible
material 
from Cooking
Surface
30" – 36
" (762 – 914 mm)
wide hood
30" – 36
" (762 – 914 mm)
wide hood
Cabinet Clearances with Hood
       as defined in the “National Fuel Gas Code” (ANSI Z223.1, Current Edition). 
Clearances from non-combustible materials are not part of the ANSI Z21.1 
scope and are not certified by CSA. 
For Gas Supply & 
Electrical Zones
see Figure 4.
For Gas Supply & 
Electrical Zones
see Figure 4.
The range height is adjustable. 
The level of the range top must 
be at the same level or above 
the counter top level.
*35 ¾" (908 mm)  Min. range 
height with leveling legs fully 
retracted.
*37 ¼"  (946 mm) Max. range 
height with leveling legs fully 
extended.
The range height is adjustable. 
The level of the range top must 
be at the same level or above 
the counter top level.
*35 ¾" (908 mm)  Min. range 
height with leveling legs fully 
retracted.
*37 ¼"  (946 mm) Max. range 
height with leveling legs fully 
extended.
30" Range Width
30" Range Width
GAS & ELECTRICAL SUPPLY ZONE
18
18
5
4⅜" 
(111 mm)
5¾"
(146 mm)
5¾"
(146 mm)
7
/
16
"
7
/
16
"
(468 mm)
13
/
16
"
(148 mm)
2" (51 mm) max. 
protrusion from wall
for gas or electrical
supply. 
2" (51 mm) max. 
protrusion from wall
for gas or electrical
supply. 
30-INCH RANGE CABINET CLEARANCES WITH HOOD