Summit TDC112C Service Manual

Page of 40
Control unit
Circuit diagram TD70.C HWC
This document must not be copied without
our written pemission, and the contents
thereof must not be imparted to a third party
nor be used for any unauthorized purpose.
Contravention will be prosecuted.
Asko Appliances AB
CIRCUIT DIAGRAM TD70.C HWC
80 902 89 - 00
WIRES IN SOME MACHINES
INTERNAL CONNECTION
NTC 1
F
SERVICE MENU
TURN OFF POWER (S1)
WAIT FOR AT LEAST 5 SEC
HOLD S2
TURN ON POWER (S1)
PRESS S2 5 TIMES TO ENTER SERVICE MENU
PRESS STOP (S3) TO CHANGE MENU STEP
ROTATE DIAL TO CHANGE IN STEP
PRESSING START (S2) STORES AND EXITS SERVICE MENU
EL 1950 W
T2
DB
N
L1
L3
L2
CM6
CM5
CM3
INKB
CM2
MO
T1
CM4
CM1
NTC 2
WIRES IN ALL MACHINES
CABLE POSITIONS
  1: THERMISTOR
  2:
COINMETER
  4: MOTOR, DRAIN PUMP, FLOAT SWITCH
  5: DOOR SWITCH
  6: COMMUNICATIONS INTERFACE
  8: POWER
  9: HEATING ELEMENT
RESISTANCES AT ROOM TEMPERATURE (CA. 20°C/68°F)
VALUES WITH +/-10% ARE REGARDED AS NORMAL
COMPONENT
        F: RADIO INTERFERENCE SUPPRESSION FILTER    680K Ohm
NTC 1: THERMISTOR 1                                                        4 - 6 K Ohm
NTC 2: THERMISTOR 2:                                                       4 - 6 K Ohm
      EL: HEATING ELEMENT 1950W                                       20.5 Ohm
    MO: MOTOR
      T1: THERMOSTAT
      T2: THERMOSTAT,
      DB: DOOR SWITCH
       CI: COMMUNICATIONS INTERFACE
      MV: MAGNETIC VALVE                                                       866 Ohm
S2 S3
S1
CI
F1
F2
3 Phase
F1
F2
USER SETTINGS MENU
TURN OFF POWER (S1)
WAIT FOR AT LEAST 5 SEC
HOLD S3
TURN ON POWER (S1)
PRESS S3 5 TIMES TO ENTER MENU
2011-07-07
MV
INKB
L
N
1 Phase
MO
MO
PHASE
BLACK
CM1
CM2
BROWN
CM5
CM4
CM3
GROUND
BLUE
CM6
BLACK
BLUE
YELLOW-
GREEN
FROM CONTROL UNIT
NEUTRAL
FROM CONTROL UNIT
If coin meter is selected CM1
and CM4 needs to be closed to
start the machine
(default closed with jumper)
CONNECTOR FOR COIN METER
Relay board
This document must not be copied without
our written pemission, and the contents
thereof must not be imparted to a third party
nor be used for any unauthorized purpose.
Contravention will be prosecuted.
Asko Appliances AB
CIRCUIT DIAGRAM TD70.C HWC
80 902 89 - 00
WIRES IN SOME MACHINES
INTERNAL CONNECTION
NTC 1
F
SERVICE MENU
TURN OFF POWER (S1)
WAIT FOR AT LEAST 5 SEC
HOLD S2
TURN ON POWER (S1)
PRESS S2 5 TIMES TO ENTER SERVICE MENU
PRESS STOP (S3) TO CHANGE MENU STEP
ROTATE DIAL TO CHANGE IN STEP
PRESSING START (S2) STORES AND EXITS SERVICE MENU
EL 1950 W
T2
DB
N
L1
L3
L2
CM6
CM5
CM3
INKB
CM2
MO
T1
CM4
CM1
NTC 2
WIRES IN ALL MACHINES
CABLE POSITIONS
  1: THERMISTOR
  2:
COINMETER
  4: MOTOR, DRAIN PUMP, FLOAT SWITCH
  5: DOOR SWITCH
  6: COMMUNICATIONS INTERFACE
  8: POWER
  9: HEATING ELEMENT
RESISTANCES AT ROOM TEMPERATURE (CA. 20°C/68°F)
VALUES WITH +/-10% ARE REGARDED AS NORMAL
COMPONENT
        F: RADIO INTERFERENCE SUPPRESSION FILTER    680K Ohm
NTC 1: THERMISTOR 1                                                        4 - 6 K Ohm
NTC 2: THERMISTOR 2:                                                       4 - 6 K Ohm
      EL: HEATING ELEMENT 1950W                                       20.5 Ohm
    MO: MOTOR
      T1: THERMOSTAT
      T2: THERMOSTAT,
      DB: DOOR SWITCH
       CI: COMMUNICATIONS INTERFACE
      MV: MAGNETIC VALVE                                                       866 Ohm
S2 S3
S1
CI
F1
F2
3 Phase
F1
F2
USER SETTINGS MENU
TURN OFF POWER (S1)
WAIT FOR AT LEAST 5 SEC
HOLD S3
TURN ON POWER (S1)
PRESS S3 5 TIMES TO ENTER MENU
2011-07-07
MV
INKB
L
N
1 Phase
MO
MO
PHASE
BLACK
CM1
CM2
BROWN
CM5
CM4
CM3
GROUND
BLUE
CM6
BLACK
BLUE
YELLOW-
GREEN
FROM CONTROL UNIT
NEUTRAL
FROM CONTROL UNIT
If coin meter is selected CM1
and CM4 needs to be closed to
start the machine
(default closed with jumper)
CONNECTOR FOR COIN METER
Relay board
Service Manual TD70.C
22