5. CHECKING OPERATION
After having fastened the top to the support structure, some simple procedures are required to check for
proper operation.
1)
Check for any gas leaks in the vicinity of the cooktop connector, the pressure regulator and the safety
valve.
WARNING
FIRE HAZARD
-
Use a soapy solution to check for proper tightness.
-
Never test for gas leaks with a match or other flames.
-
Failure to follow this instruction can result in death or fire
NOTE: The regulator Is fitted with a checkpoint outlet gas pressure to check the exact pressure supplied
to the appliance.
2)
The cooktop's electrical circuit can be checked for proper operation
only after top assembly has been completed as and you have
checked to ensure that all parts have been fitted properly:
1 a spark must light on all burners when the knobs on the top are
pressed
2 when each knob on the cooktop is pressed and turned to the
low flame symbol (
), the entire crown should light.
3 lf burners do not light properly, turn the control knob to the
"OFF" position O . Check that burner caps and crowns are in
the proper position. Check that the power supply cord is
plugged in and that circuit breaker or house fuse has not blown.
Check that the shut-off valve is in the "ON" position. Check
operation again. lf a burner does not light at this point, contact
your dealer for assistance.