Summit SCR1841BX Use & Care Manual

Page of 8
 
 
 
L is the temperature display. When O or P is pressed, L shows the compartment temperature as it is 
being set. Five seconds after O  or  P  is pressed, L  will show the actual temperature in the 
compartment. 
 
M  and  N  indicate temperature units: M  is Fahrenheit and N  is Celsius. When M  or  N  is lit, the 
temperature is shown in Fahrenheit or Celsius respectively. 
 
O and P are temperature adjustment buttons for the compartment. When you press “↑” or “↓”, the 
set temperature will rise or drop. Each time you press one of these buttons, the set temperature will 
rise or drop 1º. The temperature range for the compartment is 1~18ºC (34~64ºF). 
 
Q is the button for changing the Fahrenheit/Celsius scale. The original setting is Fahrenheit. Pressing 
Q  one time will change the display to Celsius. Press one more time and the display will revert to 
Fahrenheit. When the temperature display shows Celsius, N is lit; when the display shows Fahrenheit, 
M is lit. 
 
R  is the power switch. When the power cord is connected, press R  and the appliance will start 
working. Pressing R again will cause the appliance to stop working; the display, fan and compressor 
will all turn off. When the machine is turned off in this way (with power cord still connected), the 
temperature setting will not change when R is pressed again to turn the unit on. Even if the power 
cord is disconnected or the power is otherwise cut off,  the unit will still return to its previous set 
temperature once power is restored and R is pressed.   
NOTES: 
• 
  If the unit is unplugged or turned off, or if there has been a power failure, you must wait 3 to 5 
minutes before restarting the unit. If you attempt to restart before this time delay, the appliance 
will not start. 
• 
  When you use the appliance for the first time, or restart it after it has been shut off for a long 
time, there could be a few degrees variance between the temperature you select and the one 
indicated on the display. This is normal and due to the length of inactivation time. Once the 
appliance has been running for a few hours, everything will be back to normal.
 
• 
  You may notice condensation on the outer surface of the glass door. This occurs when water 
vapor from the air contacts the cold surface of the door and the vapor condenses on the glass, 
causing a fogging  effect. In extreme situations, water can even drip off the door, indicating 
excessive humidity in the environment.
 
• 
  If the appliance has been off for less than 5 minutes, the compressor will not restart at once 
when R is pressed. This behavior is built into the control system to protect the compressor.