BlueStar BSPC66240TS Owner's Manual

Page of 47
 
INSTALLATION GUIDE FOR FLUE (PYRAMID STYLE HOOD)
 
1.  MEASURE FROM TOP OF THE CANOPY TO CEILING AND SUBTRACT 1/8" FOR CLEAR-
ANCE. 
2.  PLACE THE DUCT COVER TOP INSIDE THE DUCT COVER BASE AND LOWER UNTIL DE-
SIRED HEIGHT IS FOUND. (TO ELIMINATE SCRATCHES, MAKE A MARK ON THE DUCT 
COVER TOP FOR THE DESIRED LOWERING POINT BY SUBTRACTING 15" FROM THE TO-
TAL HEIGHT NEEDED.) 
3.  USE THE RETAINING SCREWS TO FASTEN IN PLACE. 
4.  SLIDE THE DUCT COVER IN PLACE AND FASTEN FROM INSIDE CANOPY USING SHEET 
METAL SCREWS. 
NOTE: FOR INSTALLATIONS WITH CEILINGS ABOVE 9', USE OPTIONAL CUSTOM FLUES. SEE 
PRODUCT LITERATURE FOR DETAILS. 
       MODEL           “A” DIM        “B” MAXIMUM       “C” DIM 
 
    BS-PC30240          15”          
          27” 
            12” 
 
     BS-PC36240          15”  
          27” 
             12” 
 
     BS-PC42240          15”  
          27” 
             15” 
 
     BS-PC48240          15”  
          27” 
             18” 
 
     BS-PC54240          15”  
          27” 
             24” 
 
     BS-PC60240          15”  
          27” 
             24” 
 
     BS-PC60240          15”  
          27” 
             24” 
 
 
P/N 750306  Page   22