THE  MAKE-­‐UP  AIR  KIT  HAS  THE  ABILITY  TO  CONNECT  DIRECTLY  TO  THE  HVAC  AIR  CIRCULATION  FAN  
MOTOR.    THIS  PROVIDES  CLEANER  AND  HEALTHIER  AIR  BY  UTILIZING  THE  HVAC  FILTRATION  SYSTEM  
DURING  OPERATION  OF  OUR  RESIDENTIAL  MAKE-­‐UP  AIR  SYSTEM.
 
During  opera9on  of  the  kitchen  range  hood,  the  Air  Switch  
Assembly  will  ac9vate  the  air  circula9on  fan  motor  independently  
of  the  hea9ng  and  cooling  system  and  open  a  motorized  damper  
allowing  fresh  air  to  enter  through  the  return  air  duct.    The  
outside  air  will  then  pass  through  the  furnace  filter  prior  to  being  
distributed  throughout  the  air  supply  system.    When  air  is  no  
longer  being  exhausted  by  the  kitchen  range  hood,  the  Switch  
Assembly  and  motorized  damper  will  return  to  the  “off”  posi9on.  
This  installa9on  method  will  not  override  or  affect  the  normal  
func9on  of  the  HVAC  thermostat  or  corresponding  components.    
The  HVAC  system  will  heat  and  cool  during  opera9on  of  the  
make-­‐up  air  system  as  needed  by  measuring  the  internal  air  
temperature  of  the  home.  
UncondiIoned  outside  air  is  necessary  regardless  of  the  method  used  to  bring  it  into  the  
home  due  to  mass  balance  consideraIons.    Furthermore,  the  replenishment  air  will  require  
heaIng  or  cooling  to  the  thermostaIcally  programmed  internal  temperature  of  the  home  
whether  brought  in  by  a  make-­‐up  air  system  or  through  natural  air  infiltraIon.  
Return  Air  
Duct  
Air  Circula9on  Fan  
Filt
er
 
Air    Supply  
Duct  
Kitchen  Range  Hood  
Switch  
Assembly*  
Motorized  
Fresh    
Air    Damper  
Fresh  Air  
Intake  on  
Exterior  of  
House  
The  above  wiring  diagram  is  a  generalized  
depic9on.  Please  consult  a  licensed  HVAC  
or  electrical  contractor/professional  prior  to  
ademp9ng    any  connec9ons  to  the  HVAC  
system  or  electrical  components.    Please  
see  below  for  the  detailed  wiring  diagram.
 
R
G
C
*24V  plug-­‐in  transformer  
supplied  with  kit  is  not  
necessary  with  this  installaIon  
applicaIon  
Air  Circula9on  Fan  
The  wiring  diagram  shown  is  a  
generalized  depic9on.    Any  connec9ons  
to  the  HVAC  system  or  components  to  the  
HVAC  system  should  be  completed  by  a  
licensed  HVAC  professional.
 
R  +  
G*  
C  -­‐
   
Switch  Assembly  
Make-­‐up  Air  Kit  HVAC  Sytem  InstallaIon  Wiring  Diagram:  
*G  Represents  Air  Handler  
Fan  Motor  Control  
motorized  Fresh  Air  Damper.  
WARNING
:
 
TO  REDUCE  THE  RISK  OF  FIRE,  ELECTRICAL  SHOCK  HAZARD,  OR  INJURY  TO  PERSONS,  OBSERVE  THE  FOLLOWING:    
 
1. 
Shut  off  and  disconnect  all  power  supply  to  unit(s)  prior  to  installa9on  or  service/repair  of  device.      
2. 
Use  this  unit  only  in  manner  intended  by  manufacturer.  
3. 
All  applica9ons  of  device  must  follow  all  applicable  laws,  codes,  regula9ons,  and  standards.  
4. 
Installa9on  of  device  must  be  completed  by  a  cer9fied  installa9on  expert  or  HVAC  professional.  
5. 
For  residen9al  use  only.    Any  use  beyond  factory  recommenda9ons  voids  all  warran9es.  
OpIon  #1  -­‐  Makeup  Air  Kit  HVAC  System  InstallaIon:    
2