Cleaning the oven vent filters
The oven ventilation filters should be removed and 
cleaned often; generally at least once every month.
9
CAUTION
To avoid risk of personal injury or property damage, 
do not operate oven vent without filters properly in 
place.
1.
To remove the ventilation filters, slide the filter to the 
rear. Then pull filter downward and push to the other 
side. The filter will drop out. Repeat for the 2nd filter.
2.
Soak the ventilation filters in hot water using a mild 
detergent. Rinse well and shake to dry. Do not use 
ammonia or wash in a dishwasher. The aluminum on 
the filter will corrode and darken.
3.
To reinstall an oven ventilation filter, slide it into the 
side slot, then push up and toward oven to lock. 
Reinstall the 2nd filter using the same procedure.
Maintenance
Surface light replacement
9
CAUTION
To avoid risk of personal injury or property 
damange, wear gloves when replacing the light 
bulbs.
1.
Unplug the microwave oven or turn off power at the 
main circuit breaker.
2.
Remove the bulb cover mounting screws at both light 
positions under the microwave.
3.
Replace bulb with 30 watt appliance bulb.
4.
Replace bulb cover and mounting screw.
5.
Plug the microwave back into the power supply or turn 
the power back on at the main circuit breaker.
Plastic & Controls
When cool, clean with soapy water, rinse and dry.
Printed areas  
(words & numbers)
Do not use abrasive cleaners or petroleum based solvents.
Part
Recommendations