Whirlpool G7CE3635X Installation Instruction

Page of 16
6
Make Electrical Connection
This cooktop is manufactured with a frame connected, green or 
bare ground wire. Connect the cooktop cable to the junction box 
through the UL listed or CSA approved conduit connector.
Electrical Connection Options
4-Wire Cable from Power Supply to 4-Wire Cable from 
Cooktop
IMPORTANT: Use the 4-wire cable from power supply where 
local codes do not permit connecting the frame-ground 
conductor to the neutral (white) junction box wire.
1. Disconnect power.
2. Remove junction box cover, if present.
3. Connect the flexible cable conduit from the cooktop to the 
junction box using a UL listed or CSA approved connector for 
½" (1.3 cm) conduit.
4. Tighten screws on conduit connector if present.
5. Connect the two black wires together using the UL listed wire 
connectors.
6. Connect the two red wires together using the UL listed wire 
connectors.
7. Connect the two white wires together using the UL listed wire 
connectors.
8. Connect the green or bare ground wire from the cooktop 
cable to the green or bare ground wire (in the junction box) 
using the UL listed wire connectors.
9. Install junction box cover.
10. Reconnect power.
For cooktops with a 4-wire cable:
If your home has:
And you will be 
connecting to:
Go to Section:
4-wire direct
A fused 
disconnect or 
circuit breaker 
box
4-Wire Cable from 
Power Supply to 
4-Wire Cable from 
Cooktop
3-wire direct
A fused 
disconnect or 
circuit breaker 
box
3-Wire Cable from 
Power Supply to 
4-Wire Cable from 
Cooktop
For cooktops with a 3-wire cable:
If your home has:
And you will be 
connecting to:
Go to Section:
4-wire direct
A fused 
disconnect or 
circuit breaker 
box
4-Wire Cable from 
Power Supply to 
3-Wire Cable from 
Cooktop
3-wire direct
A fused 
disconnect or 
circuit breaker 
box
3-Wire Cable from 
Power Supply to 
3-Wire Cable from 
Cooktop
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Use 8 gauge copper wire.
Electrically ground cooktop.
Failure to follow these instructions can result in death, 
fire, or electrical shock.
(12.7 cm)
5"
(8.9 cm)
3
¹⁄₂
"
(12.7 cm)
5"
(8.9 cm)
3
¹⁄₂
"
A. 4-wire cable from power supply
B. Black wires
C. Bare or green wires
D. 4-wire cable from cooktop
E. Junction box
F. White wires
G. UL listed wire connector
H. Red wires
I. UL listed or CSA approved 
conduit connector
A
B
C
D
E
F
G
H
I