Gas Dryer Grounding
IMPORTANT: The dryer must be electrically grounded in 
accordance with local codes and ordinances or, in the absence 
of local codes, with the National Electrical Code, ANSI/NFPA 
70, latest edition, or Canadian Electrical Code, CSA C22.1. 
If codes permit and a separate ground wire is used, it is 
recommended that a qualified electrical installer determine  
that the ground path is adequate.
A copy of the above code standards can be obtained from:
National Fire Protection Association 
One Batterymarch Park, Quincy, MA 02269
CSA International 
8501 East Pleasant Valley Road 
Cleveland, Ohio 44131-5575
 
Do not ground to a gas pipe.
 
Do not have a fuse in the neutral or ground circuit.
 
 A 120 volt, 60 Hz, AC only, 15- or 20-amp, fused electrical 
circuit is required. A time-delay fuse or circuit breaker is also 
recommended. It is recommended that a separate circuit 
serving only this dryer be provided.
 
This dryer is equipped with a power supply cord having a 
3-prong grounding plug.
 
 To minimize the possibility of shock, the cord must be 
plugged into a mating, 3 prong, grounding-type outlet, 
grounded in accordance with local codes and ordinances. 
If a mating outlet is not available, it is the personal 
responsibility and obligation of the customer to have the 
properly grounded outlet installed by a qualified electrician.
 
 If codes permit and a separate ground wire is used, it is 
recommended that a qualified electrician determine that the 
ground path is adequate.
 
 Check with a qualified electrician if you are not sure the 
dryer is properly grounded.
GAS DRYER INSTALLATION REQUIREMENTS
Electrical Requirements
GROUNDING INSTRUCTIONS
SAVE THESE INSTRUCTIONS
■  
For a grounded, cord-connected dryer: 
This dryer must be grounded. In the event of malfunction or 
breakdown, grounding will reduce the risk of electric shock 
by providing a path of least resistance for electric current. 
This dryer is equipped with a cord having an equipment- 
grounding conductor and a grounding plug. The plug must 
be plugged into an appropriate outlet that is properly 
installed and grounded in accordance with all local codes 
and ordinances.
WARNING: 
Improper connection of the equipment- 
grounding conductor can result in a risk of electric shock. 
Check with a qualified electrician or service representative 
or personnel if you are in doubt as to whether the dryer is 
properly grounded. Do not modify the plug provided with 
the dryer: if it will not fit the outlet, have a proper outlet 
installed by a qualified electrician.