Amana NED5800DW Quick Setup Guide

Page of 24
12
Connect neutral ground wire (E) and neutral wire (white or 
center wire) (C) of power supply cord or cable under center, 
terminal block screw (B). Tighten screw.
Place ends of remaining wires under outer terminal block 
screws. Tighten screws. 
Connect a separate copper ground wire (G) under the green 
external ground conductor screw (A) to an adequate ground. 
Finally, reinsert tab of terminal block cover into slot of dryer 
rear panel. Secure cover with hold-down screw. Now, go to 
“Venting Requirements.” 
IMPORTANT: You must verify with a qualified electrician that this 
grounding method is acceptable before connecting.
Optional External Ground for 3-Wire  
Connection
 (
Power Supply Cord Shown)
2. 
Connect neutral ground wire and  
neutral wire
C
E
B
1. 
Prepare to connect neutral ground 
wire and neutral wire
E
B
A
3. 
Connect remaining wires
4. 
Connect external ground wire
G
A
Install the correct strain relief for your electrical connection 
method, as shown on page 8 or 10. 
Remove center terminal block screw (B). Remove neutral ground 
wire (E) from green external ground conductor screw (A).
Venting Requirements
VENTING
WARNING: 
To reduce the risk of fire, this dryer MUST BE 
EXHAUSTED OUTDOORS.
IMPORTANT: Observe all governing codes and ordinances.
Dryer exhaust must not be connected into any gas vent, 
chimney, wall, ceiling, attic, crawlspace, or a concealed space 
of a building. Only rigid or flexible metal vent shall be used for 
exhausting.
4"
(102 mm)
4" (102 mm) heavy metal exhaust vent
 
Only a 4" (102 mm) heavy metal exhaust vent and clamps  
may be used. 
 
Do not use plastic or metal foil vent.