All gas pipe connections to the heater must be sealed with gas pipe compound or Teflon sealing tape. Prior to use, the 
gas supply line should be checked for leaks by applying a mild solution of soap and water. Never use an open flame to 
check for leaks. See section titled ‘Checking for Gas Leaks’, page 10. 
Run the gas line to the vicinity of the heater.  It is recommended that the gas line be securely fixed to the wall or 
mounting surface. WARNING: do not run gas line in a location that it can be tripped over or in a location that passes 
by
 either the heat output or the exhaust of the heater. This gas line can now be attached directly to the heater using a 
series of elbows and short sections of straight pipe (nipples), sufficient to lead gas piping from the wall to the inlet of the 
heater. The final fitting will be a ½”NPT male pipe to mount directly into the heater.  A convenient alternative to this 
termination point is to run a flexible gas line directly from the termination point of the hard piping to the inlet of the 
heater. This typical flexible line would  be ½” I.D. (5/8” O.D.) stainless steel, with ½” MIP (male) fittings at both ends. 
(Lynx P/N  31546).  A ½” FIP (female) coupling would then be used to connect the flex line to the hard pipe. Please note, 
for Natural Gas (NG) installations, a regulator is not required, as the heater is equipped with a built-in regulator inside 
the valve.  For Propane (LP) installations, always use the regulator that is provided with the propane flexible 
connection hose. 
An alternative to the hard pipe installation (NG or LP) is to use a flexible hose which mounts directly from the main gas 
source and extends directly into the heater inlet. Lynx provides such a hose. Please order Lynx P/N LQD-EM  if this type 
of installation is desired. See illustrations below for all three installation techniques.