Installation Requirements
MINIMUM INSTALLATION CLEARANCES - Inches (cm)
SIDES
REAR
TOP
FRONT
 Alcove
0” (0 cm)
0” (0 cm)*
0” (0 cm)
n/a
 Under Counter
0” (0 cm)
0” (0 cm)*
0” (0 cm)
n/a
Clearance requirements
Closet Installation
NOTE
Because of potentially inconsistent voltage capabilities, 
the use of this dryer with power created by gas powered 
generators, solar powered generators, wind powered 
generators or any other generator other than the local utility 
company is not recommended.
NOTE
Dryers manufactured for sale in Canada have factory-
installed, 4-wire power supply cord (NEMA 14-30R).
Electrical requirements for electric dryer
3-WIRE POWER SUPPLY CORD KIT (not supplied)
OUTLET RECEPTACLE - NEMA 10-30R or NEMA 14-30R 
receptacle to be located so the power supply cord is 
accessible when the dryer is in the installed position.
GROUNDING CONNECTION - See “Grounding requirements” 
in Electrical Installation section.
The dryer MUST employ a 3-conductor power supply cord 
NEMA 10-30 type SRDT rated at 240 volt AC minimum, 30 
amp, with 3 open end spade lug connectors with upturned 
ends or closed loop connectors and marked for use with 
clothes dryers. For 3-wire cord connection instructions see 
ELECTRICAL CONNECTIONS FOR A 3-WIRE SYSTEM.
4-WIRE POWER SUPPLY CORD KIT (not supplied)
The dryer MUST employ a 4-conductor power supply 
cord NEMA 14-30 type SRDT or ST (as required) rated 
at 240 volt AC minimum, 30 amp, with 4 open end 
spade lug connectors with upturned ends or closed loop 
connectors and marked for use with clothes dryers. For 
4-wire cord connection instructions see ELECTRICAL 
CONNECTIONS FOR A 4-WIRE SYSTEM.
3-wire receptacle
(NEMA type 10-30R)
4-wire receptacle
(NEMA type 14-30R)
IMPORTANT
This dryer is internally grounded to neutral unless it was 
manufactured for sale in Canada.
Only a 4-conductor cord shall be used when the appliance 
is installed in a location where grounding through the 
neutral conductor is prohibited. Grounding through 
the neutral link is prohibited for: (1) new branch circuit 
installations, (2) mobile homes, (3) recreational vehicles, 
and (4) areas where local codes do not permit grounding 
through the neutral.
Manufactured or mobile home installation
Installation MUST conform to current Manufactured Home 
Construction & Safety Standard, Title 24 CFR, Part 32-80 
(formerly the Federal Standard for Mobile Home Construction 
and Safety, Title 24, HUD Part 280) or Standard CAN/
CSAZ240 MH.
CIRCUIT - Individual 30 amp. branch circuit fused with 30 
amp. time delay fuses or circuit breakers. Use separately 
fused circuits for washer and dryer. DO NOT operate a 
washer and a dryer on the same circuit.
POWER SUPPLY - 3-wire or 4-wire, 208-240 volt, single 
phase, 60 Hz, Alternating Current.
If installing the dryer in a closet, the unit must only be 
operated with the door in the open position to allow correct air 
circulation. See Use and Care Guide for more information.