Best WC45E90SB Specification Sheet
WC45E SERIES WIRING
WC45E SERIES
MOUNTING
a. Minimum hood distance above cook top must not be less than 24”. A maximun of 30” above
cook top is highly recommended for best capture of cooking impurities. Distances over 30” are
at the installer and user’s discretion; and if ceiling height and flue length permit.
b. Requires optional 10-ft. to 11-ft. flue extension, ducted model AEWC345
I
QSB.
HOOD DISTANCE ABOVE 36” HIGH COOK TOP (see note below)
30”
MOUNTING BRACKET CENTER HOLE LOCATION ABOVE 36” HIGH COOK TOP
CEILING
HEIGHT
8 FEET
24”
25”
26”
27”
28”
29”
WOOD CROSS
SUPPORT BEHIND
DRYWALL
DRYWALL
DUCTED
DUCT
METHOD
FRAMING
BEHIND WOOD
CROSS SUPPORT
CENTERLINE
3-1/2”
3-1/2”
2-3/16”
9 FEET
DUCTED
10 FEET
(see note b.)
DUCTED
DUCTED
11 FEET
(see notes
a. & b.)
37-11/16”
37-11/16”
37-11/16”
37-11/16”
38-11/16”
38-11/16”
38-11/16”
38-11/16”
39-11/16”
39-11/16”
39-11/16”
39-11/16”
40-11/16”
40-11/16”
40-11/16”
40-11/16”
41-11/16”
41-11/16”
41-11/16”
41-11/16”
42-11/16”
42-11/16”
42-11/16”
42-11/16”
43-11/16”
43-11/16”
43-11/16”
43-11/16”
CONNECT:
WHITE-TO-WHITE,
RED-TO-BLACK,
GREEN-TO-GROUND.
EXTERIOR OR
IN-LINE BLOWER
BLOWER CONNECTION AT HOOD
BOX MARKED
“MOTOR
CONNECTION”
120 VOLT 60 HZ
GROUNDED WALL
OUTLET OFFSET
FROM DUCT
CENTER LINE
(STAY WITHIN 4”
DIMENSION)
GROUNDED WALL
OUTLET OFFSET
FROM DUCT
CENTER LINE
(STAY WITHIN 4”
DIMENSION)
18½”
to
19½”
4”
8”
CENTERLINE
OF HOOD
15
7
/
8
”
22
5
/
8
”