Fire Magic 36VH6 Installation Instruction

Page of 26
REV 2 - 1406051400
L-C2-387
9
R O O F  (8ft)
VENT PIPING
Install 10" round galvanized (single wall) vent piping as required. 
Installation will depend on roof construction. 
DUCT COVER
(To enclose transition and area above hood. Some installs may not 
require a duct cover, as countertop height & roof height may vary. )
S
P
A
C
E
R
R
E
A
R
W
A
L
L
(N
O
N
C
O
M
B
U
S
T
I
B
L
E)
HOOD
Transition
GAS 
GRILL
(rear of vent hood 
must align with 
rear of grill oven)
30-33"
Note:  Drawings are not to scale.
Fire Magic offers a spacer and duct cover specifi cally designed for your vent hood. Reference the 
information below for an overall orientation. 
(Contact your dealer for ordering information.)
In order to use these prefabricated components, ensure the component dimensions allow for an appropriate 
install as addressed below (as individual setups may vary).
REFER TO INSTALLATION SECTION FOR COMPLETE DETAILS REGARDING ALL INFORMATION FOUND ON THIS PAGE.
INSTALLATION REQUIREMENTS - FIRE MAGIC SPACER & DUCT COVER
(bracket)
•  THIS VENT HOOD IS FOR OUTDOOR, WALL MOUNT INSTALLATION ONLY.
•  Installation must be done by a qualifi ed professional service technician.
•  Below is a diagram of a generic installation.
•  Please review and understand this section prior to proceeding with installation.
Alternatively, a custom spacer and soffi t can be constructed that is appropriate for your individual setup. 
See the following page for details.
The Spacer depth is based upon 8" between a non-combustible wall 
and the rear of the grill (i.e. 4" backsplash + 4" required clearance).
The Duct Cover height is based upon a 33" - 36" countertop height 
and an 8' high ceiling.
DUCT CO
VER
SP
ACER
8"
18"
Width varies
by model:
(36", 42", 48", 60")
20 
1
/
4
"
12"
Width varies
by model:
(36", 42", 48", 60")