17
Specification and Performance 
Data Sheet
For filter model: 9000 077 095 
Using replacement cartridge: 9000 077 104 
The model was tested by NSF International with 
reference to ANSI/NSF Standards 42 & 53 
and certified for a reduction in the substances cited 
below.
The concentration of the indicated substances which 
are dissolved in water and penetrate the system was 
reduced to a value below or equal to the permitted limit 
value in accordance with NSF/ANSI 42 and 53 for 
water discharged out of the appliance.
Note:
Even though the tests were conducted under standard 
laboratory conditions, the actual performance may 
deviate from these tests.
* Based on the use of Cryptosporium parvum ocysts.
Application guidelines / Water supply parameters:
The system is to be installed and operated 
according to the guidelines recommended by 
the manufacturer.
The filter is to be changed every 6-9 months.
Rinse new filter thoroughly for 5 minutes.
More detailed information can be found on 
the warranty card.
Without appropriate disinfection before and after 
connecting it to the system, this product should NOT 
be used if the water is microbiologically 
contaminated or if the quality has not been 
ascertained. A system certified for cyst reduction 
should be used for disinfected water which possibly 
contains filterable cysts.
A one-year warranty is issued for the entire system 
(except disposable cartridge). With reference 
to disposable cartridges a warranty is issued for 
material and processing faults only. As the service life 
of disposable cartridges depends on the local water 
conditions, no warranty is issued for them.
More detailed information on the prices of spare parts 
is available from your appliance dealer or parts 
salesman on site.
Manufactured by:
Cuno Engineered Products
1000 Apollo Road
Eagan, MN 55121-2240 U.S.A.
The system was tested and certified on 
model 9000 077 095 by NSF International 
with reference to ANSI/NSF Standard 53 
for a reduction in cysts and turbidity, as 
well as with reference to ANSI/NSF 
Standard 42 for a reduction in the taste 
and odor of chlorine.
Nominal particle class: I
Nominal service life: 
739.68 gallons (2,800 litres)
Substance Average in 
inflow
Inflow 
concentration
Waste water 
concentration
Average
reduction 
as %
Max. permitted 
concentration 
in waste water
Max. 
waste
water
Min. 
reduction 
as %
NSF test
Cysts *
166,500
Min. 50,000/l
1
99.99
99.95
1
99.99
511077-03
Turbidity
10.7
11 x 1 NTU
0.3 l
97.10
0.5 NTU
0.49
95.42
511078-03
Particle 
class 1 
particle 
size > 0.5 
to < 1.0 μm
5,700,000
At least
10,000 particles/ml
30.583
99.52
> 85%
69.000
98.9
511079-03
Taste 
of chlorine 
and 
turbidity
1.9
2.0 mg/l + - 10%
0.05
97.3
> 50%
0.06
96.84
511081-03
Water Pressure
30 - 120 psi 
(207 - 827 kPa)
Water Temperature *
33 °F - 100 °F 
(0.6 °C - 38 °C)
Flow Rate
0.75 gpm (2.83 l/min.)