Kobe IS24XGSQB1 Owner's Manual

Page of 22
 
15 
 
 
TROUBLE SHOOTING 
 
Issue 
Possible Cause 
Solution 
After 
Installation, 
both motors 
and lights are 
not working. 
The power is not on. 
Make sure the circuit 
breaker and the unit’s 
power is ON. Use a voltage meter to check the 
power supply. 
The wire connection is not secure. 
Check and tighten wire connection. 
The control panel is defective. 
Replace the control panel. 
Lights are 
working, but 
motor(s) is not. 
 
The motor(s) is defective. 
Replace the motor. 
The capacitor(s) is defective. 
Replace capacitor(s). 
The control panel is defective. 
Replace the control panel. 
The range 
hood is 
vibrating. 
The blower system is not secure. 
 
Tighten the turbine impeller/squirrel cage and air 
chamber. 
The turbine impeller/squirrel cage is 
not balanced. 
Replace the turbine impeller/squirrel cage. 
Hood is not secured in place. 
Check the installation of hood, tighten the 
mounting bracket. 
The motor is 
working, but 
the lights are 
not working. 
 
LED light fixture(s) is defective. 
 
Replace LED light fixture(s) 
The light wiring(s) is loose. 
 
Check wire continuity from processor board to 
light transformer to LED light fixture(s). 
The control panel or LED light driver is 
defective. 
 
Replace the control panel or LED light driver. 
 
The range 
hood is not 
venting out 
correctly. 
 
The range hood is installed outside of 
the manufacture recommended 
clearance. 
 
Adjust the clearance between the range hoods 
and cook top to 26
” to 30”. For Island range 
hood, the clearance between the range hoods 
and cook top is 30” to 36”. 
There is no make-up air inside the 
house. 
Open the window to enhance the performance 
of the range hood by creating a sufficient make-
up air. 
Obstacle blocking the pipe work. 
 
Remove all obstacles from the duct work. 
The pipe size is smaller than the 
suggested pipe size. 
Change the ducting according to the 
manufacture suggestion. 
Cold air is 
coming into the 
home. 
The pipe connection is not properly 
sealed.  
Check the pipe installation. 
 
The damper is not properly installed or 
is missing from the installation. 
Check the damper installation. 
 
The damper is not installed. 
Installing the damper will help eliminate air 
backflow.