Whirlpool WFE515S0ES Installation Instruction

Page of 16
10
4. Use a Phillips screwdriver to connect the green ground wire 
from the power supply cord to the range with the ground-link 
screw and ground-link section. The ground wire must be 
attached first.
5. Use 
³⁄₈" nut driver to connect the neutral (white) wire to the 
center terminal block post with one of the 10–32 hex nuts.
6. Connect line 2 (red) and line 1 (black) wires to the outer 
terminal block posts with 10-32 hex nuts.
7. Securely tighten hex nuts.
NOTE: For power supply cord replacement, use only a power 
cord rated at 250 volts minimum, 40 amps or 50 amps that is 
marked for use with nominal 1
³⁄₈" (3.5 cm) diameter 
connection opening, with ring terminals and marked for use 
with ranges.
8. Tighten strain relief screws.
9. Replace terminal block access cover.
3-wire connection: Power Supply Cord
Use this method only if local codes permit connecting chassis 
ground conductor to neutral wire of power supply cord.
1. Feed the power supply cord through the strain relief on the 
cord/conduit plate on bottom of range. Allow enough slack to 
easily attach the wiring to the terminal block.
2. Use 
³⁄₈" nut driver to connect the neutral (white) wire to the 
center terminal block post with one of the 10–32 hex nuts.
3. Connect line 2 (red) and line 1 (black) wires to the outer 
terminal block posts with 10-32 hex nuts.
4. Securely tighten hex nuts.
NOTE: For power supply cord replacement, use only a power 
cord rated at 250 volts minimum, 40 amps or 50 amps that is 
marked for use with nominal 1
³⁄₈" (3.5 cm) diameter 
connection opening, with ring terminals and marked for use 
with ranges.
5. Tighten strain relief screws.
6. Replace terminal block access cover.
Direct Wire Installation: Copper or Aluminum Wire
This range may be connected directly to the fuse disconnect or 
circuit breaker box. Depending on your electrical supply, make 
the required 3-wire or 4-wire connection.
1. Strip outer covering back 3" (7.6 cm) to expose wires. Strip 
the insulation back 
³⁄₈" (1.0 cm) from the end of each wire.
2. Allow enough slack in the wire to easily attach the wiring 
terminal block.
3. Complete electrical connection according to your type of 
electrical supply (4-wire or 3-wire connection).
4-wire Connection: Direct Wire
Use this method for:
New branch-circuit installations (1996 NEC)
Mobile homes 
Recreational vehicles
In an area where local codes prohibit grounding through the 
neutral
A. 10–32 hex nut
B. Ground-link screw
C. Line 2 (red)
D. Green ground wire
E. Neutral (center) wire 
F. Line 1 (black)
A. Terminal block
B. Ground-link screw
C. UL listed strain relief
D. Power supply cord wires - large opening
A
B
C
F
D
E
A
B
D
C
A. 10–32 hex nut
B. Line 2 (red)
C. Ground-link screw
D. Neutral (white) wire
E. Line 1 (black)
A
B
C
D
E
3"
(7.6 cm)
³⁄₈
"
(1.0 cm)