Electrical Installation
Electrical Requirements
You can find the identification plate with the electrical 
specifications on the underside of the appliance. The 
junctionbox must be located within 3 feet of the cooktop 
connection. It should be easily accessible for service 
purposes.
Power supply
Connect Electrical Supply
9
WARNING
Before installing, turn off at the service panel. Lock 
service panel to prevent power from being turned 
on accidentally.
The electrical power supply system should be a 1-phase, 
3-wire system with ground connection. Install suitable 
junction box (not furnished). An appropriately-sized, UL-
listed conduit connector must be used to correctly attach 
the conduit to the junction box.
The branch-circuit breakers ampacity, the wire sizes and 
the connections must be conform to the requirements of 
the National Electrical Code or Canadian Electrical Code 
and all local codes and ordinances.
Attach flexible conduit to the junction box.
9
WARNING
To reduce the risk of electric shock and fire, do not 
use a flexible power supply cord.
Connect the cooktop lead wires to the junction box 
supply wires in proper phase: 
black (L1) to black
red (L2) to red
blank copper wire to ground
Check the Installation
9
CAUTION
Before you plug in an electrical cord or turn on 
power supply, make sure all controls are in the OFF 
position.
Remove everything from the cooktop surface including 
stickers. Clean cooktop surface with cooktop cleaning 
creme.
Switch on the circuit breaker.
Verify that elements function properly.
Model
240 V AC, 60 Hz 
system: circuit 
breaker
208 V AC, 60 Hz 
system: circuit 
breaker
NETP666SUC 40 Amp
40 Amp
NETP066SUC 40 Amp
40 Amp
NET8666UC
40 Amp
40 Amp
NET8066UC
40 Amp
30 Amp
NET8666SUC 40 Amp
40 Amp
NET8066SUC 40 Amp
30 Amp
NEM5666UC 40 Amp
40 Amp
NEM5066UC 30 Amp
30 Amp
 PP )LWWLQJ&RQGXLW PP
 PP $SSUR[LPDWH
-ER[
&RQGXLWDSSUR[