Allied Telesis AT-MC103XL AT-MC103XL-10 Data Sheet

Product codes
AT-MC103XL-10
Page of 2
Ordering Information
AT-MC101XL-xx
UTP to multi-mode ST (2km) fiber
AT-MC102XL-xx
UTP to multi-mode SC (2km) fiber
AT-MC103XL-xx
UTP to single-mode SC (15km) fiber
AT-MC103LH-xx
UTP to single-mode long-haul SC (40km) fiber
Where xx =
10 (US power adapter)
20 (European power adapter)
30 (UK power adapter)
40 (Australian power adapter)
Associated Products
AT-TRAY1
Rack-mounting tray for one Media Converter
AT-TRAY4
Rack-mounting tray for up to four Media Converters
AT-WLMT
Wall-mount bracket for one Media Converter
AT-MCR12
12 slot AC/DC powered chassis for Media Converters
MC10x series 
| Fast Ethernet Media Converters
USA Headquarters 
|
19800 North Creek Parkway 
|
Suite 200 
|
Bothell 
|
WA 98011 
|
USA 
|
T: +1 800 424 4284 
|
F: +1 425 481 3895
European Headquarters 
|
Via Motta 24 
|
6830 Chiasso 
|
Switzerland 
|
T: +41 91 69769.00 
|
F: +41 91 69769.11
Asia-Pacific Headquarters 
|
11 Tai Seng Link 
|
Singapore 
|
534182 
|
T: +65 6383 3832 
|
F: +65 6383 3830
www.alliedtelesis.com
© 2007 Allied Telesis Inc. All rights reserved. Information in this document is subject to change without notice. All company names, logos, and product designs that are trademarks or registered trademarks are the property of their respective owners.
617-00275-00 Rev G
Link Test
The link test is a fast and easy way for you to test the
connections between the media converter ports and the
end-nodes that are connected to the ports. If a network
problem occurs, you can perform a link test to
determine which port is experiencing a problem, and  be
able to focus your troubleshooting efforts on the cable
or end-node where the problem resides.
MissingLink
TM
The MissingLink
TM
feature enables the two ports on the
media converter to pass the ‘Link’ status of their
connections to each other. When the media converter
detects a loss of connection to an end-node, the media
converter shuts down the connection to the other port,
thus notifying the end-node that the connection has
been lost.
Technical Specifications
Status Indicators
Front Panel
Power
Indicates power is applied to the
converter
Link (2)
Indicates a valid receive link exists
Activity (2)
Indicates TX/RX on the port
FDX
Indicates full-duplex operation
ML
Indictaes MissingLink
TM
enabled
Switches
ML - Link Test
Enable MissingLink
TM
A/N
Enable Auto-negotiation
Packet Transmission  Characteristics
Round Trip Delay
0.4µs Maximum
Bit Error Rate (BER)
<10-12
Twisted Pair Interface
Min.
Typical Max.
UTP Differential 
Output Voltage 
950mv 980mv 1050mv
Overshoot Voltage 
4% 
5%
Single Amplitude 
Symmetry 0.98 
1.0062 
1.02
Rise and Fall Time
Rise 
3.0ns 4.6ns 5.0ns
Fall 
3.0ns 4.2ns 5.0ns
Rise and Fall Time 
Symmetry
0.4ns 
0.5ns
Power Characteristics
External Power Supply
120V AC, 60Hz (US model)
240V AC, 50Hz 
(European models)
Input Supply Voltage
12vDC
Max Current
500mA
Power Consumption 
6W
Environmental Specifications
Operating Temp
0°C to 40°C 
(32°F to 104°F)
Storage Temp.
–20°C to 80°C
Relative Humidity 
5% to 95% non-condensing
Operating Altitude
0 to 10,000 feet
RoHS Compliant
Physical Characteristics
Dimensions:
10.5cm x 9.5cm x 2.5cm
(W x D x H)
(4.12” x 3.75” x 1.0”)
Weight:
294g (10.4oz)
Electrical/Mechanical Approvals
EMC
FCC Class B
Safety compliant
UL-Cul, CSA/CSA, NRTL,
TUV, CE compliant
Port Type
(Connector)
Cable
Distance
Optical
Frequency
Launch Power (dBm)
Receive Power (dBm)
Max.
Avg.
Min.
Min.
Sensitivity
Typical
Sensitivity
Saturation
100FX MMF (2km)
2km
1310nm
-14.0
-16.8
-19.0
-31.8
-34.5
-14.0
100FX SMF (15km)
15km
1310nm
-8.0
-11.5
-15.0
-31.0
-31.0
-8.0
100FX SMF (40km)
40km
1310nm
0.0
-3.0
-5.0
-35.0
-38.0
0.0