8
INSTALLATION
CAUTION:  During installation, persons installing the hood must wear heavy gloves 
to protect against sharp edges.
POSITIONING THE RANGE HOOD
Upon  completion  of  installation,  the  distance  between  the  hood  and    an  electric 
rangetop must be a minimum of 25" (65cm), and the distance between the hood and a 
gas rangetop must be a minimum of 30" (75cm).
                       
min. 30" for gas ranges  
min. 25" for electric ranges  
PREPARING THE SITE
WARNING – TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY, 
OBSERVE THE FOLLOWING:
a.
Installation  work  and  electrical  wiring  must  be  done  by  quali?ed  personnel  in 
accordance  with  all  applicable  codes  and  standards,  including  ?re-rated 
construction.
b.
Sufficient air is needed for proper combustion and exhausting of gases through 
the ?ue (chimney) of fuel-burning equipment to prevent backdrafting.  Follow the 
range manufacturer's guidelines and safety standards such as those published by 
the  National  Fire  Protection  Association  (NFPA),  the  American  Society  for 
Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local 
code authorities.
c.
When cutting or drilling into wall or ceiling, do not damage electrical wiring and 
other hidden utilities.
d.
Ducted fans must always be vented to the outdoors.
EXPLODED VIEW
SEH1524
2121.6.579.01
1
1
2
3
5
4
6
7
8
8
9
10
12
13
14
16
17
18
19
20
21
15
11
Exploded View For 24" Model