Asko T884XLHPW Owner's Manual

Page of 24
16
Customer Care Center, 1-800-898-1879, www.askona.com
INSTALLATION
See the separate installation instructions included in the 
set of documents.
ELECTRICAL INSTALLATION
Connect the machine by plugging it into an earthed wall 
socket. The electrical wall socket must be placed outside 
of the installation area to be easily accessible. 
CONNECTION ON DELIVERY
•  208-240 V, 1-phase, 15 A
•  60 Hz
•  Heat output 3000 W
•  Use a type A residual-current device.
SWITCH-OVER
The switchover must be performed by a qualified 
electrician.
1.  The switchover must be performed by a qualified 
electrician.
2.  Press and hold the Temperature selection button and 
then press the main power switch.
3.  Turn the programme selector and choose between: 
Heater 2 On (3000 W/15 A) and Heater 2 Off (1950 
W/10 A). 
4.  Press the Start button once to save your selection.
 WARNING !
Risk of fire.
Install the clothes dryer according to the manufacturer’s 
instructions and local codes.
Do not install a clothes dryer with flexible plastic 
venting materials. If flexible metal (foil type) duct is 
installed, it must be of a specific type identified by 
the applience manufacturer that is UL approved for 
use with clothes dryers. Flexible venting materials are 
known to collapse, be easily crushed, and trap lint. 
These conditions will obstruct clothes dryer airflow and 
increase the risk of fire.
To reduce the risk of of severe injury or death, follow all 
installation instructions.
SAVE THESE INSTRUCTIONS FOR FUTURE 
REFERENCE.
POSITIONING THE TUMBLE DRYER
The tumble dryer can be freestanding or stacked. 
Remember that the tumble dryer produces heat and 
should therefore not be located in a room that is too small. 
If the room is very small, drying will take longer due to the 
limited quantity of air.
 WARNING !
•  Clothes dryer installation must be performed by a 
qualified installer.
•  For proper ventilation, the machine should not be 
installed behind a door.
•  The tumble dryer’s toe kick ventilation must not be 
blocked by a rug or the like.
NOTE!
If the unit must be installed behind a door, the door 
should be louvered. (please see door ventilation 
requirements in the Built-in chapter). To improve 
ventilation, the door where the tumble dryer is located 
should be left open when the dryer is in use.
Freestanding
The tumble dryer can be positioned beside the washing 
machine.
Stacking
The tumble dryer can be placed on top of a ASKO 
washing machine. In this case you use the stacking 
attachments (foot cups and anti-tilt devices) that come 
with the machine. Two rubber feet and two anti-tipping 
brackets are supplied in the bag found in the drum of the 
dryer.
INSTALLATION