Bosch HMV8052U Installation Instruction

Page of 32
11
Adapting microwave blower
This microwave is shipped assembled for Room Venting 
Installation. The blower unit is already in place and must 
not to be adapted.
Adapting microwave blower for roof venting
1.
Remove and save the screws holding the blower 
motor and the blower plate. Lift up the blower plate 
and put it aside.
2.
Carefully pull out the blower unit and rotate 90º so that 
fan blade openings are facing out the top of the 
microwave.
3.
Place the blower unit back into the opening.
9
CAUTION
Do not pull or stretch the blower unit wiring. Make 
sure the wires are not pinched, and that they are 
properly secured.
4.
Replace the blower plate and secure with the screws 
removed in step 1.
5.
Attach the exhaust adapter to the top of the blower 
plate by sliding it into the guides. Push in securely until 
it is in the locking tabs. Make sure the damper hinge 
swings freely.
Adapting microwave blower for wall venting
1.
Remove and save the screws holding the blower 
motor and the blower plate. Lift up the blower plate 
and put it aside.
2.
Carefully pull out the blower unit and rotate 90º so that 
fan blade openings are facing out the top of the 
microwave.
3.
Rotate the blower unit counterclockwise 180º.