Bosch HCB56651UC Installation Instruction

Page of 40
9
Safety clearances
9
WARNING
RISK OF FIRE
Grease deposits in the grease filter can catch fire. 
The given safety clearance must be observed to 
avoid heat buildup. Observe the specifications for 
your cooking appliance. If gas and electric cooktops 
are used together, the largest given clearance 
applies.
The appliance may only be installed directly next to 
a cabinet or wall on one side. The wall or cabinet 
clearance must be at least 2" (50 mm). 
The clearance between the shelf on the cooktop and the 
bottom of the extractor hood may not be less than 24" 
(610 mm) in the case of electric cooktops and 30" (760 
mm) in case of gas or combined ranges.
If the installation instructions for the gas cooking 
appliance specify a larger distance, this must be taken 
into account.
Electric cooktop
Gas cooktop
Fan operation
Note:  Ventilation may not exit through an already 
operational smoke or exhaust chimney, nor a duct used 
for ventilating furnace installation areas.
If the ventilation is intended to pass through a smoke 
or exhaust that is not in operation, the responsible 
area heating inspector must give approval.
If the ventilation passes through an external wall, use a 
telescope wall sleeve.
Ventilation line
Note:  The device manufacturer does not assume any 
warranty for complaints attributable to the pipe section.
The ventilation opening and the exhaust air ducts must 
be made according to the local circumstances.
The device achieves its optimum performance by 
means of a short, straight exhaust air pipe and as 
large a pipe diameter as possible.
As a result of long rough exhaust air pipes, many pipe 
bends or too-small diameters, the optimum extraction 
performance is not achieved and fan noise is 
increased.
The pipes or hoses for laying the exhaust air line must 
consist of non-combustible material.
Smooth the connection area of the pipes before 
installation.
Seal the connection points of the pipes appropriately.
Round pipes
An inner diameter of Ø 8" (200 mm) is recommended.
Flat ducts
The inner cross-section must correspond to the diameter 
of the round pipes.
Ø 8" (200 mm) approx. 50.3 inches
2
 (324 cm
2
)
Flat ducts should have no sharp deflections.
Use sealing strip for deviating pipe diameters.
Checking the wall
The wall must be level, vertical and adequately load-
bearing.
The depth of the bore holes must be the same length 
as the screws. The wall plugs must have a secure grip.
The enclosed screws and wall plugs are suitable for 
solid brickwork. Suitable fasteners must be used for 
other structures.