Appliance dimensions
Power Requirements
The outlet must be properly grounded in accordance with 
all applicable codes.
It can be installed inside the cabinet above the 
appliance.
Electrical Installation
Electrical Requirements:
a three prong grounded outlet
120 V, 60 Hz, AC only
20 Amp electrical supply with a fuse or a circuit 
breaker
This product must be connected to a supply circuit of the 
proper voltage and frequency. Wire size must conform to 
the requirements of the National Electric Code or the 
prevailing local code for this rating. The power supply 
cord and plug should be brought to a separate 20-amp 
branch circuit single grounded outlet. The outlet box 
should be located inside the cabinet above the appliance 
(see section Location Requirements). The outlet box and 
supply circuit should be installed by a qualified 
electrician and conform to the National Electrical Code or 
the prevailing local code.
The voltage used must be the same as specified on this 
microwave oven. Using a higher voltage is dangerous 
and may result in a fire or oven damage. Using a lower 
voltage will cause slow cooking. The dealer is not 
responsible for any damages resulting from the use of 
the oven with any voltage other than specified.