Gaggenau VG295114CA Installation Instruction

Page of 28
8
Conversion to another type of gas
This gas stovetop corresponds to the categories 
specified on the rating plate. By changing nozzles, it 
is possible to convert the appliance to any of the 
gases listed on the plate. The conversion kit can be 
obtained from our customer service. With some 
models, the conversion kit is included in the scope of 
delivery. 
Only a licensed specialist is authorized to switch the 
appliance to another gas type.
Before carrying out the conversion, turn off the 
electricity and gas supply.
Changing the low burn nozzle
1
Remove pan supports and all burner parts.
2
Remove control knobs. Unscrew fastening screws 
(three 7 mm nuts on each burner and two Torx 
T20 on the wok burner) and and carefully detach 
stovetop.
3
The low burn nozzles are located in the gas valve 
and are screwed in from above. Turn the black 
plastic part so that the recess is above the nozzle. 
Screw out nozzle and take nozzle out with small 
pliers.
4
Insert the new nozzles as specified in the nozzle 
table. The nozzles must be screwed in fully.
Changing the full burn nozzle: normal and large 
burner
1
Remove securing clips on the burner pipes. 
Remove burner pipes. Leave the electrode 
connected. Unscrew burners (Torx T20) and and 
pull off the burner from the burner pipes.
2
Remove nozzles and O-ring by hand.
3
Check that O-ring is correctly positioned in new 
full-burn nozzles. Push nozzles onto burner pipes. 
Do not bend burner pipes!
4
Push the burners onto the supply lines. Put on 
securing clips. Screw the burners back on.
5
Set air-regulating tube to correct dimension after 
loosening the screw (see nozzle table). Tighten 
screw again.
/