Monogram ZIFS360NXRH Installation Instruction

Page of 24
Installation Instructions
16
STEP 6  SECURE UNIT TO WALL
• The “L” rods can be found in the upper left and right
corners of the unit in the access compartment. 
Look through the access compartment to make 
sure the rods line up with the anti-tip bracket.
• There are 2 washers and a hair pin cotter per rod.
Remove the washers and hair pin cotter from the end
of the rod.
• Rotate and move the “L” rod into the slot in the anti-tip
bracket tab. Once it is in the slot, rotate the “L” rod 
so the hook portion is pointing down. The holes 
at the front end of the rod should be in a vertical 
position. Do this to both sides.
• Pull out on the end of the rod to make sure it is secure
in the bracket. 
• Locate the hole on the rod that is closest to the unit. 
A hair pin cotter will be put through this hole to secure
the rod. If this hole appears to be too far away for 
a snug fit against the unit, add the washers one 
at a time until the pin will fit tightly into the hole.
• Align the straight section of the pin with the hole from
the underside of the rod. Push the pin up until it snaps
into position. Pliers may be used. NOTE: The hair pin
cotter must be vertical when this step is completed to
ensure the “L” rod is engaged in the bracket.
• Check the rod for tightness by pulling forward. 
If the rod moves, remove the hair pin cotter and place
another washer on the rod. Reinsert the pin. 
• Bend the left grille back into place (freezer only) and
replace the screws.
• Replace the flat grille panel by sliding it under the
flange at the top of the access compartment and
pushing the grille back into place. Replace screws.