Monogram ZDP486NDPSS Installation Instruction

Page of 68
Installation Preparation
4-WIRE POWER CORD INSTALLATION
NOTE: A 4-wire cord is connected to the range 
at the factory. Use the following steps to change
an existing installation from a 3-wire cord back 
to a 4-wire cord.
WARNING
The neutral wire of the supply circuit must 
be connected to the neutral terminal located 
in the lower center of the terminal block. 
The power leads must be connected 
to the lower left and the lower right 
terminals of the terminal block. The 4th
grounding lead must be connected to 
the frame of the range with the ground 
plate and the ground screw.
•Remove the 3 lower terminal screws from 
the terminal block. Remove the ground screw 
and ground plate and retain them.
Remove the ground strap. DO NOT DISCARD
THE GROUND STRAP OR ANY SCREWS.
•Insert the one ground screw into the power cord
ground wire terminal ring, through the ground
plate and into the frame of the range.
•Insert the 3 terminal screws (removed earlier)
through each power cord terminal ring and 
into the lower terminals of the terminal block.
Be certain that the center wire (white/neutral) 
is connected to the center lower position 
of the terminal block. Tighten screws securely 
into the terminal block.
Before
After
Terminal 
Block
Terminal 
Block
Neutral
Terminal
Neutral Terminal
Ground Strap
Ground Plate
(grounding to
range)
Ground
Screw
Ground Strap 
or
3-WIRE POWER CORD INSTALLATION
NOTE: A 4-wire cord is connected to the range 
at the factory. Use the following steps to change
the range to a 3-wire cord.
WARNING
The neutral or ground wire of the power cord 
must be connected to the neutral terminal located
in the center of the terminal block. The power leads
must be connected to the lower left and the lower
right terminals of the terminal block.
•Remove the ground strap (located at the right 
side of the terminal block) and connect between
the center lower portion of the terminal block 
to the frame of the range.
•Remove the 3 lower terminal screws from 
the terminal block. Insert the 3 terminal screws
through each power cord terminal ring and 
into the lower terminals of the terminal block.
Be certain that the center wire (white/neutral) 
is connected to the center lower position 
of the terminal block. Tighten screws securely 
into the terminal block.
DO NOT remove the ground strap connection.
Ground
Strap
Terminal Block 
(appearance
may vary)
Neutral
Terminal
Power Cord
Ground 
Plate
10