Monogram ZV1050SFSS Installation Instruction

Page of 16
6
Advance Planning
DUCT FITTINGS
Total
Equivalent Quantity Equivalent
Duct Piece Dimensions
Length*
Used
Length
Round,
1 ft.
straight
(per foot
length)
1 ft.
3-1/4" x 12"
(per foot
straight
length)
90
° elbow
17 ft.
45
° elbow
10 ft.
3-1/4" x 12"
90
° elbow
43 ft.
3-1/4" x 12"
45
° elbow
26 ft.
3-1/4" x 12"
90
° flat elbow
102 ft.
8" round to
3-1/4" x 12" transition
2 ft.
3-1/4" x 12"
to 8" round transition
5 ft.
8" round
to 3-1/4" x 12"
transition 90
° elbow
6 ft.
3-1/4" x 12" to 8"
round transition 90
° elbow 13 ft.
Round
wall cap
with damper
32 ft.
3-1/4" x 12" wall cap
with damper
75 ft.
Round
roof cap
44 ft.
Use this chart to compute maximum
permissible lengths for duct runs to
outdoors.
Note: Do not exceed maximum permissible
equivalent lengths!
Maximum duct length:
100 ft. for range hoods.
Flexible ducting:
If flexible metal ducting is used, all
the equivalent feet values in the table
should be doubled. The flexible metal
duct should be straight and smooth
and extended as much as possible.
Do NOT use flexible plastic ducting.
Total Duct Run
Note: Any home ventilation system, such as a ventilation
hood, may interrupt the proper flow of combustion air and
exhaust required by fireplaces, gas furnaces, gas water
heaters and other naturally vented systems. To minimize
the chance of interruption of such naturally vented
systems, follow the heating equipment manufacturer’s
guidelines and safety standards such as those published
by NFPA and ASHRAE.
* Actual length of straight duct plus duct fitting
equivalent. Equivalent length of duct pieces are based
on actual tests conducted by GE Evaluation Engineering
and reflect requirements for good venting performance
with any ventilation hood.
This Hood Must
Use 8" Round Duct.
It Can Transition to