Monogram ZDP304NPSS Manual

Page of 132
Care and Cleaning
Professional  Dual  Fuel  Range
The door is very heavy. Be careful when removing
and lifting the door.
Do not lift the door by the handle. 
To remove the door:
1. Fully open the door.
2. Pull the hinge locks down toward the door
frame, to the unlocked position. A tool, such as 
a small flat-blade screwdriver, may be required.
3. Firmly grasp both sides of the door at the top.
4. Close door to the door removal position,
(approximately 15 degrees from closed) and 
lift it up and out until the hinge arm is clear 
of the slot.
To replace the door:
1. Firmly grasp both sides of the door at the top.
2. With the door at the same angle as the
removal position, seat the indentation of the
hinge arm into the bottom edge of the hinge
slot. The notch in the hinge arm must be fully
seated into the bottom of the slot.
3. Fully open the door. If the door will not fully open,
the indentation is not seated correctly in the
bottom edge of the slot.
4. Push the hinge locks up against the front frame
of the oven cavity, to the locked position.
5. Close the oven door.
Lift-off
oven door
Hinge arm
Indentation
Bottom
edge of
slot
Removal position
Hinge lock
Slot
Pull hinge locks down to unlock
Hinge
lock
Hinge
arm
Push hinge locks up to lock
Probe
Allow the temperature probe to cool before
cleaning.
The probe should be cleaned with soap and
water by hand.
Do not immerse the temperature probe in water. 
Do not store the temperature probe in the oven.
Do not clean the temperature probe in the 
self-cleaning oven.
31
Replacement position