ELECTRICAL REQUIREMENTS (230V/208V)
Provisions should be made to have the proper 
electrical outlet near the case. All wiring should be 
made in accordance with local codes and regulations. 
The line cord will extend to a wall receptacle located
within the area shown in the table below.
Wall Receptacles
All wiring should be made in accordance with local 
electrical codes and regulations.
See the Owner’s Manual for how to connect electrical 
supply. 
NOTE: 
Aluminum wiring in structure may pose 
special problems—consult a qualified electrician.
A
Inside
120V/115V 12 amp
230V/208V 20 amp
“tandem” type
“perpendicular” type
DRAIN KIT (optional)
If it is necessary to install a drain kit on this wall case, 
the following kit is available:
RAD4A1 External Drain
This external drain will carry condensate water away
from the unit and the building.
To install:
1. 
Cut off the solid end of the rubber plug (approx.
1/8″). Be sure the hole is open through the length
of the plug. Insert the plug through the drain hole 
in the corner of the cabinet. (Immersing the rubber 
plug in denatured alcohol or soap suds will make 
this easier.)
2. Insert the drain fitting into the rubber plug.
3. Attach a field-supplied drain tube to the drain 
fitting. Install strain relief clamps to the drain  
tube to prevent leaks due to mechanical strain  
or vibration.
4. A non-hardening sealant should be applied where 
the rubber plug fits into the cabinet and where  
the drain fitting meets the rubber plug.
5. If metallic tubing is used as a drain tube, a short 
length of rubber or plastic tubing should be used to 
connect the drain fitting to the drain tube. This will 
prevent mechanical strain to the drain fitting and 
reduce vibration transmission from the unit to  
the drain tube. 
6. If an architectural rear grille is used in this 
installation, it is necessary to cut a small triangular 
section from the lower right corner of the grille to 
provide adequate space for the drain tube.
NOTE: 
It may be desirable or necessary to install 
the drain kit on the case prior to installing the case 
into the wall.
Cabinet
Rubber  
plug
Drain 
fitting
  MODEL 
“A” 
“B”
 
115V 
47″
72″
  230/208V  39″
65″