VENTING   REQUIREMENTS
Determine which venting method is best for your application.  
Ductwork can extend either through the wall or the roof.
The length of the ductwork and the number of elbows should 
be  kept  to  a  minimum  to  provide  efficient  performance.  
The size of the ductwork should be uniform.  Do not install 
two elbows together.  Use duct tape to seal all joints in the 
ductwork system.  Use caulking to seal exterior wall or floor 
opening around the cap.
Flexible ductwork is not recommended.  Flexible ductwork 
creates  back  pressure  and  air  turbulence  that  greatly 
reduces performance.
Make sure there is proper clearance within the wall or floor 
for exhaust duct before making cutouts.  Do not cut a joist 
or stud unless absolutely necessary.  If a joist or stud must 
be cut, then a supporting frame must be constructed
FOR MORE SPECIFIC DUCTWORK INFORMATION, GO 
TO PAGE 4.
WARNING - To Reduce The Risk Of Fire, Use Only Metal Ductwork.
• Venting system MUST terminate outside the 
home.
• DO NOT terminate the ductwork in an attic or 
other enclosed space.
• DO NOT use 4" laundry-type wall caps.
• Flexible-type ductwork is not recommended.
• DO NOT obstruct the flow of combustion and 
ventilation air.
• Failure to follow venting requirements may result 
in a  fire.
This appliance should be connected directly to the fused 
disconnect  (or  circuit  breaker)  through  flexible,  armored 
or nonmetallic sheathed copper cable.  Allow some slack 
in the cable so the appliance can be moved if servicing is 
ever necessary.  A UL Listed, 1/2" conduit connector must 
be provided at each end of the power supply cable (at the 
appliance and at the junction box).
When making the electrical connection, cut a 1   1/4" hole 
in the wall.  A hole cut through wood must be sanded until 
smooth.  A hole through metal must have a grommet. 
WARNING - TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, do 
not use this fan with any solid-state speed control device.
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR 
INJURY TO PERSONS, OBSERVE THE FOLLOWING:  Use this unit only 
in the manner intended by the manufacturer.  If you have any ques-
tions, contact the manufacturer.
Before servicing or cleaning unit, switch power off at service panel 
and lock the service disconnecting means to prevent power from 
being switched on accidentally.  When the service disconnecting 
means  cannot  be  locked,  securely  fasten  a  prominent  warning 
device, such as a tag, to the service panel.
CAUTION: For General Ventilating Use Only.  Do Not Use To Exhaust 
Hazardous  or  Explosive Materials and Vapors.
WARNING  -  TO  REDUCE  THE  RISK  OF  FIRE,  ELECTRICAL  SHOCK, 
OR  INJURY  TO  PERSONS,  OBSERVE  THE  FOLLOWING:  Installation 
Work And Electrical Wiring Must Be Done By Qualified Person(s) 
In Accordance With All Applicable Codes And Standards, Including 
Fire-Rated Construction.  
Sufficient air is needed for proper combustion and exhausting of 
gases through the flue (chimney) of fuel burning equipment to prevent 
backdrafting.  Follow the heating equipment manufacturer's guideline 
and safety standards such as those published by the National Fire 
Protection Association (NFPA), and the American Society for Heat-
ing, Refrigeration and Air Conditioning Engineers (ASHRAE), and the 
local code authorities.
When cutting or drilling into wall or ceiling, do not damage electrical 
wiring and other hidden utilities.
Ducted fans must always be vented to the outdoors.
   WARNING
• Electrical ground is required on this rangehood.
• If cold water pipe is interrupted by plastic, 
nonmetallic gaskets or other materials, DO NOT 
use for grounding.
• DO NOT ground to a gas pipe.
• DO NOT have a fuse in the neutral or grounding 
circuit.  A fuse in the neutral or grounding circuit 
could result in electrical shock.
• Check with a qualified electrician if you are in 
doubt as to whether the rangehood is properly 
grounded. 
• Failure to follow electrical requirements may result 
in a fire.   
   WARNING
ELECTRICAL REQUIREMENTS
A 120 volt, 60 Hz AC-only electrical supply is required on a 
separate 15 amp fused circuit.  A time-delay fuse or circuit 
breaker is recommended.  The fuse must be sized per local 
codes in accordance with the electrical rating of this unit as 
specified  on  the  serial/rating  plate  located  inside  the  unit 
near the field wiring compartment.  THIS UNIT MUST BE 
CONNECTED WITH COPPER WIRE ONLY.  Wire sizes must 
conform to the requirements of the National Electrical Code, 
ANSI/NFPA 70 - latest edition, and all local codes and ordi-
nances.  Wire size and connections must conform with the 
rating of the appliance.  Copies of the standard listed above 
may be obtained from: 
 
National Fire Protection Association
 
Batterymarch Park
 
Quincy, Massachusetts  02269
For residential use only.
!
!
Cold Weather installations
 additional back draft damper should be installed to minimize 
backward cold air flow and a nonmetallic thermal break should 
be installed to minimize conduction of outside temperatures 
as part of the vent system. The damper should be on the cold 
air side of the thermal break. The break should be as close as 
possible to where the vent system enters the heated portion 
of the house.
CAUTION
 - To reduce risk of fire and to properly exhaust 
air, be sure to duct air outside – Do not vent exhaust air into 
spaces within walls or ceilings or into attics, crawl spaces, 
or garages.